Manual
Table Of Contents
- 1 Disclaimers
- 2 Safety information
- 3 Notice to user
- 4 Customer help
- 5 Quick Start Guide
- 6 Description
- 7 Operation
- 7.1 Charging the battery
- 7.2 Turning on and turning off the camera
- 7.3 Saving an image
- 7.4 Recalling an image
- 7.5 Deleting an image
- 7.6 Deleting all images
- 7.7 Measuring a temperature using a spotmeter
- 7.8 Measuring the hottest temperature within an area
- 7.9 Measuring the coldest temperature within an area
- 7.10 Hiding measurement tools
- 7.11 Changing the color palette
- 7.12 Working with color alarms
- 7.13 Changing image mode
- 7.14 Changing the temperature scale mode
- 7.15 Changing the camera temperature range
- 7.16 Setting the emissivity as a surface property
- 7.17 Setting the emissivity as a custom material
- 7.18 Changing the emissivity as a custom value
- 7.19 Changing the reflected apparent temperature
- 7.20 Changing the distance between the object and the camera
- 7.21 Performing a non-uniformity correction (NUC)
- 7.22 Configuring Wi-Fi
- 7.23 Changing the settings
- 7.24 Updating the camera
- 8 Mechanical drawings
- 9 CE Declaration of conformity
- 10 Cleaning the camera
- 11 Application examples
- 12 Thermographic measurement techniques
- 13 About calibration
- 13.1 Introduction
- 13.2 Definition—what is calibration?
- 13.3 Camera calibration at FLIR Systems
- 13.4 The differences between a calibration performed by a user and that performed directly at FLIR Systems
- 13.5 Calibration, verification and adjustment
- 13.6 Non-uniformity correction
- 13.7 Thermal image adjustment (thermal tuning)
- 14 About FLIR Systems
Operation
7
Follow this procedure:
1. Push the navigation pad to display the menu system.
2. Select
(Settings) and push the navigation pad. This displays the Settings menu.
3. Select Camera temperature range and push the navigation pad. This displays a dia-
log box.
4. Select the appropriate temperature range and push the navigation pad.
7.16 Setting the emissivity as a surface
property
To measure temperatures accurately, the camera must know what kind of surface you
are measuring. You can choose between the following surface properties:
• Matt.
• Semi-matt.
• Semi-glossy.
For more information about emissivity, see section 12 Thermographic measurement
techniques, page 34.
Follow this procedure:
1. Push the center of the navigation pad. This displays a toolbar.
2. On the toolbar, select Settings
. This displays a dialog box.
3. In the dialog box, select Measurement parameters. This displays a dialog box.
4. In the dialog box, select Emissivity. This displays a dialog box.
5. In the dialog box, select one of the following:
• Matt.
• Semi-matt.
• Semi-glossy.
7.17 Setting the emissivity as a custom
material
Instead of specifying a surface property as matt, semi-matt or semi-glossy, you can spec-
ify a custom material from a list of materials.
For more information about emissivity, see section 12 Thermographic measurement
techniques, page 34.
Follow this procedure:
1. Push the center of the navigation pad. This displays a toolbar.
2. On the toolbar, select Settings
. This displays a dialog box.
3. In the dialog box, select Measurement parameters. This displays a dialog box.
4. In the dialog box, select Emissivity. This displays a dialog box.
5. In the dialog box, select Custom material. This displays a list of materials with known
emissivities.
6. In the list, select the material.
7.18 Changing the emissivity as a custom
value
For very precise measurements, you may need to set the emissivity, instead of selecting
a surface property or a custom material. You also need to understand how emissivity and
reflectivity affect measurements, rather than just simply selecting a surface property.