Quick Connection Guide

427-0089-00-28 Rev 160 June 2020
This document does not contain any export-controlled information.
Step 4 Connect a ground wire between the ground stud on the back
of the camera and the nearest earth-grounding point.
Step 5 Tighten Cable seal gland nut to ensure a watertight seal.
Step 6 Replace cover: Alternately tighten the four captive screws in
the cover; torque to 1.8 N-m (16.0 in-lbs).
Step 7 Discover camera: Power the camera. With a PC connected
to the camera network, use the DNA utility to discover and
display the camera’s current IP address.
a. Download the DNA utility from the product web page at:
https://www.flir.com/browse/security/thermal-security-cameras/
b. Un-zip the utility, then double-click and run the executable file
DNA.exe. All the units on the VLAN are discovered.
c. Select the camera, then select Assign IP to change the IP address.
When set to DHCP, if a DHCP server is not on the network, the
address will default to 192.168.0.250.
d. Double-click the camera in DNA’s Discovery List. The unit’s Login
window opens in a web browser.
e. Enter the User Name (“admin”) and default password (“admin”). The
camera’s web page opens.
f. For additional instructions on using DNA, refer to the DNA User’s
Manual available in the Help ( ) link while the software is running.
Step 8 Mount camera. Typically direct the
camera towards the ground with a tilt
angle α of 45° to 60°. Include as little
skyline as possible in the field of view.
Step 9 Calibrate Analytics. FC-Series ID only
a. On the camera’s Setup > Analytics web page, ensure analytics is
on (green button) and click the Calibration Tools icon.
b. To automatically calibrate detection settings, from the Calibration
Mode drop-down list, select Auto.
c. Click Relearn. The camera automatically calibrates the depth.
Ensure a person is walking throughout the FoV until finished.
d. The On-Screen Display shows the auto calibration progress as a
percentage in the upper corner of the video. If the auto calibration