User's Manual
Table Of Contents
- 1 Disclaimers
- 2 Safety information
- 3 Introduction
- 4 Description
- 5 Operation
- 5.1 Powering the meter
- 5.2 Moisture measurements
- 5.3 Hygrometric measurements
- 5.4 IR temperature measurements
- 5.5 Condensation measurements
- 5.6 Vapor pressure measurements
- 5.7 Selecting measurement units
- 5.8 Storing and recalling measurements
- 5.9 Alarm settings
- 5.10 Locked mode
- 5.11 Streaming measurement data using Bluetooth
- 6 Maintenance
- 7 Material groups
- 8 Technical specifications
- 9 Technical support
- 10 Warranties

8 Technical specifications
8.4 Thermal measurement range specifications
Function IR range Accuracy (of reading)
IR temperature (8:1
ratio)
–20 to –1℃ (–4 to 31℉) ±5℃ (±9℉)
0℃ (32℉) ±1℃ (±2℉)
1 to 200℃ (33 to
392℉)
Greater of ±3.5% or
±5℃ (±9℉)
IR Emissivity 0.95 (fixed)
Sensor temperature -28 to 77 ℃ (-18 to 170
℉)
±2 ℃ (3.6 ℉)
8.5 Vapor pressure specifications
Function Range Accuracy (of reading)
Vapor pressure
measurement
–1 to 60℃ (30 to 140℉)
0.0–20.0 kPa Greater of ±2.0% or 0.2
kPa
Dew Point Temperature
range
-30 to 100 ℃ (-22 to
199 ℉)
Mixing Ratio range
0-999 GPP (0 to 160 g/
kg)
#T559822; r.9065/9080; en-US 25