User's Manual Part 2
Table Of Contents
- 15 Working with image modes
- 16 Working with measurement tools
- 16.1 General
- 16.2 Adding/removing measurement tools
- 16.3 Working with user presets
- 16.4 Resizing or moving a measurement tool
- 16.5 Changing object parameters
- 16.6 Displaying values in the result table and displaying a graph
- 16.7 Creating and setting up a difference calculation
- 16.8 Setting a measurement alarm
- 17 Fetching data from external FLIR meters
- 18 Working with color alarms and isotherms
- 19 Annotating images
- 20 Programming the camera (time lapse)
- 21 Recording video clips
- 22 Screening alarm
- 23 Changing settings
- 24 Technical data
- 24.1 Online field-of-view calculator
- 24.2 Note about technical data
- 24.3 Note about authoritative versions
- 24.4 FLIR T600 15° (incl. Wi-Fi and Ext. cal.)
- 24.5 FLIR T600 15° (incl. Wi-Fi)
- 24.6 FLIR T600 25° (incl. Wi-Fi and Ext. cal.)
- 24.7 FLIR T600 25° (incl. Wi-Fi)
- 24.8 FLIR T600 25° and 15° w/case
- 24.9 FLIR T600 25° and 45° w/case
- 24.10 FLIR T600 45° (incl. Wi-Fi and Ext. cal.)
- 24.11 FLIR T600 45° (incl. Wi-Fi)
- 24.12 FLIR T600bx 25° (incl. Wi-Fi and Ext. cal.)
- 24.13 FLIR T600bx 25° (incl. Wi-Fi)
- 24.14 FLIR T600bx 45° (incl. Wi-Fi and Ext. cal.)
- 24.15 FLIR T600bx 45° (incl. Wi-Fi)
- 24.16 FLIR T610 15° (incl. Wi-Fi)
- 24.17 FLIR T610 25° (incl. Wi-Fi)
- 24.18 FLIR T610 45° (incl. Wi-Fi)
- 24.19 FLIR T620 15° (incl. Wi-Fi and Ext. cal.)
- 24.20 FLIR T620 15° (incl. Wi-Fi)
- 24.21 FLIR T620 25° (incl. Wi-Fi and Ext. cal.)
- 24.22 FLIR T620 25° (incl. Wi-Fi)
- 24.23 FLIR T620 25° and 15° (incl. Wi-Fi)
- 24.24 FLIR T620 25° and 45° (incl. Wi-Fi)
- 24.25 FLIR T620 45° (incl. Wi-Fi and Ext. cal.)
- 24.26 FLIR T620 45° (incl. Wi-Fi)
- 24.27 FLIR T620bx 15° (incl. Wi-Fi and Ext. cal.)
- 24.28 FLIR T620bx 15° (incl. Wi-Fi)
- 24.29 FLIR T620bx 25° (incl. Wi-Fi and Ext. cal.)
- 24.30 FLIR T620bx 25° (incl. Wi-Fi)
- 24.31 FLIR T620bx 45° (incl. Wi-Fi and Ext. cal.)
- 24.32 FLIR T620bx 45° (incl. Wi-Fi)
- 24.33 FLIR T630 15° (incl. Wi-Fi)
- 24.34 FLIR T630 25° (incl. Wi-Fi)
- 24.35 FLIR T630 45° (incl. Wi-Fi)
- 24.36 FLIR T630sc 15° (incl. Wi-Fi)
- 24.37 FLIR T630sc 25° (incl. Wi-Fi)
- 24.38 FLIR T630sc 25° and 45° w/case
- 24.39 FLIR T630sc 45° (incl. Wi-Fi)
- 24.40 FLIR T640 15° (incl. Wi-Fi and Ext. cal.)
- 24.41 FLIR T640 15° (incl. Wi-Fi)
- 24.42 FLIR T640 25° (incl. Wi-Fi and Ext. cal.)
- 24.43 FLIR T640 25° (incl. Wi-Fi)
- 24.44 FLIR T640 25° and 15° (incl. Wi-Fi)
- 24.45 FLIR T640 25° and 45° (incl. Wi-Fi)
- 24.46 FLIR T640 45° (incl. Wi-Fi and Ext. cal.)
- 24.47 FLIR T640 45° (incl. Wi-Fi)
- 24.48 FLIR T640bx 15° (incl. Wi-Fi and Ext. cal.)
- 24.49 FLIR T640bx 15° (incl. Wi-Fi)
- 24.50 FLIR T640bx 25° (incl. Wi-Fi and Ext. cal.)
- 24.51 FLIR T640bx 25° (incl. Wi-Fi)
- 24.52 FLIR T640bx 45° (incl. Wi-Fi and Ext. cal.)
- 24.53 FLIR T640bx 45° (incl. Wi-Fi)
- 24.54 FLIR T650sc 15° (incl. Wi-Fi)
- 24.55 FLIR T650sc 25° (incl. Wi-Fi)
- 24.56 FLIR T650sc 25° and 15° w/case
- 24.57 FLIR T650sc 25° and 45° w/case
- 24.58 FLIR T650sc 45° (incl. Wi-Fi)
- 24.59 FLIR T660 15° (incl. Wi-Fi and Ext. cal.)
- 24.60 FLIR T660 15° (incl. Wi-Fi)
- 24.61 FLIR T660 25° (incl. Wi-Fi and Ext. cal.)
- 24.62 FLIR T660 25° (incl. Wi-Fi)
- 24.63 FLIR T660 25° and 15° w/case
- 24.64 FLIR T660 25° and 45° w/case
- 24.65 FLIR T660 45° (incl. Wi-Fi and Ext. cal.)
Working with color alarms and
isotherms
18
18.1 Color alarms
18.1.1 General
By using color alarms (isotherms), anomalies can easily be discovered in an infrared im-
age. The isotherm command applies a contrasting color to all pixels with a temperature
above, below, or between the set temperature levels. The camera also features isotherm
types that are specific to the building trade: condensation and insulation alarms.
You can make the camera trigger the following types of color alarms:
• Above alarm: This will apply a contrasting color to all pixels with a temperature above
the specified temperature level.
• Below alarm: This will apply a contrasting color to all pixels with a temperature below
the specified temperature level.
• Interval alarm: This will apply a contrasting color to all pixels with a temperature be-
tween two specified temperature levels.
• Condensation alarm: Triggers when the camera detects a surface where the relative
humidity exceeds a preset value.
• Insulation alarm: Triggers when there is an insulation deficiency in a wall.
18.1.2 Image examples
This table explains the different color alarms (isotherms).
Color alarm
Image
Above alarm
Below alarm
#T559880; r. AL/45866/46124; en-US
53