User's Manual
Table Of Contents
- 1 Disclaimers
- 2 Safety information
- 3 Notice to user
- 4 Customer help
- 5 Quick start guide
- 6 Register the camera
- 7 Camera parts
- 8 Screen elements
- 9 Navigating the menu system
- 10 Handling the camera
- 10.1 Charging the battery
- 10.2 Removing the battery
- 10.3 Turning on and turning off the camera
- 10.4 Adjusting the infrared camera focus manually
- 10.5 Autofocusing the infrared camera
- 10.6 Continuous autofocus
- 10.7 Saving an image
- 10.8 Operating the laser distance meter
- 10.9 Measuring areas
- 10.10 Connecting external devices and storage media
- 10.11 Moving files to a computer
- 10.12 Assigning functions to the programmable button
- 10.13 Using the camera lamp as a flash
- 10.14 Hand strap
- 10.15 Lanyard strap
- 10.16 Wrist strap
- 10.17 Front protection
- 10.18 Changing camera lenses
- 10.19 Calibrating the compass
- 11 Saving and working with images
- 12 Working with the image archive
- 13 Achieving a good image
- 14 Working with image modes
- 15 Working with measurement tools
- 15.1 General
- 15.2 Adding/removing measurement tools
- 15.3 Editing user presets
- 15.4 Moving and resizing a measurement tool
- 15.5 Changing the measurement parameters
- 15.6 Displaying values in the result table and displaying a graph
- 15.7 Creating and setting up a difference calculation
- 15.8 Setting a measurement alarm
- 16 Working with color alarms and isotherms
- 17 Annotating images
- 18 Programming the camera (time-lapse)
- 19 Recording video clips
- 20 Screening alarm
- 21 Pairing Bluetooth devices
- 22 Configuring Wi-Fi
- 23 Fetching data from external FLIR meters
- 24 Changing settings
- 25 Cleaning the camera
- 26 Technical data
- 26.1 Online field-of-view calculator
- 26.2 Note about technical data
- 26.3 Note about authoritative versions
- 26.4 FLIR E75 24°
- 26.5 FLIR E75 42°
- 26.6 FLIR E75 24° + 14°
- 26.7 FLIR E75 24° + 42°
- 26.8 FLIR E75 24° + 14° & 42°
- 26.9 FLIR E85 24°
- 26.10 FLIR E85 42°
- 26.11 FLIR E85 24° + 14°
- 26.12 FLIR E85 24° + 42°
- 26.13 FLIR E85 24° + 14° & 42°
- 26.14 FLIR E95 24°
- 26.15 FLIR E95 42°
- 26.16 FLIR E95 24° + 14°
- 26.17 FLIR E95 24° + 42°
- 26.18 FLIR E95 24° + 14° & 42°
- 27 Mechanical drawings
- 28 Application examples
- 29 About FLIR Systems
- 30 Definitions and laws
- 31 Thermographic measurement techniques
- 32 About calibration
- 32.1 Introduction
- 32.2 Definition—what is calibration?
- 32.3 Camera calibration at FLIR Systems
- 32.4 The differences between a calibration performed by a user and that performed directly at FLIR Systems
- 32.5 Calibration verification and adjustment
- 32.6 Non-uniformity correction
- 32.7 Thermal image adjustment (thermal tuning)
- 33 History of infrared technology
- 34 Theory of thermography
- 35 The measurement formula
- 36 Emissivity tables
Working with measurement tools15
15.4.3 Moving and resizing a box or circle tool
Note You can also move and resize the measurement tool by touching the screen.
Follow this procedure:
1. To select the measurement tool, touch the tool on the screen. The tool is now dis-
played with one or more handles.
2. Push the navigation pad—or touch and hold the tool. This displays a context menu.
3. Select
(Move/resize) and push the navigation pad. This displays a submenu.
4. Use the navigation pad to select one of the following:
• Select
(Resize) to change the size of the tool.
• Select
(Move) to move the tool.
• Select
(Center box/circle) to center the box or circle tool.
5. Push the navigation pad up/down and left/right to resize or move the tool.
6. When completed, push the navigation pad and select
(Done).
7. Push the navigation pad to confirm and exit the menu mode.
15.5 Changing the measurement parameters
15.5.1 General
For accurate measurements, it is important to set the measurement parameters.
Note During normal operation there is typically no need to change the default meas-
urement parameters, see section 15.5.3 Recommended values, page 67.
15.5.2 Types of parameters
The camera can use these measurement parameters:
• External IR window compensation, i.e., the temperature of any protective windows,
external lenses (e.g., the close-up lens), etc., that are set up between the camera and
the object of interest. If no protective window, protective shield, or external lens is
used, this value is irrelevant and should be left inactive.
• Object distance, i.e., the distance between the camera and the object of interest.
Note The camera can be configured to automatically measure the distance when
an image is saved. With this setting, the Object distance parameter is automatically
updated with the measured distance when an image is saved. For more information,
see section 7.3 Laser distance meter and laser pointer, page 19.
• Atmospheric temperature, i.e., the temperature of the air between the camera and the
object of interest.
• Relative humidity, i.e., the relative humidity of the air between the camera and the ob-
ject of interest.
• Reflected temperature, which is used when compensating for the radiation from the
surroundings reflected by the object into the camera. This property of the object is
called “reflectivity.”
• Emissivity, i.e., how much radiation an object emits, compared with the radiation of a
theoretical reference object at the same temperature (called a “blackbody”). The