User's Manual
Table Of Contents
- 1 Disclaimers
- 2 Safety information
- 3 Notice to user
- 4 Customer help
- 5 Quick start guide
- 6 Register the camera
- 7 Camera parts
- 8 Screen elements
- 9 Navigating the menu system
- 10 Handling the camera
- 10.1 Charging the battery
- 10.2 Removing the battery
- 10.3 Turning on and turning off the camera
- 10.4 Adjusting the infrared camera focus manually
- 10.5 Autofocusing the infrared camera
- 10.6 Continuous autofocus
- 10.7 Saving an image
- 10.8 Operating the laser distance meter
- 10.9 Measuring areas
- 10.10 Connecting external devices and storage media
- 10.11 Moving files to a computer
- 10.12 Assigning functions to the programmable button
- 10.13 Using the camera lamp as a flash
- 10.14 Hand strap
- 10.15 Lanyard strap
- 10.16 Wrist strap
- 10.17 Front protection
- 10.18 Changing camera lenses
- 10.19 Calibrating the compass
- 11 Saving and working with images
- 12 Working with the image archive
- 13 Achieving a good image
- 14 Working with image modes
- 15 Working with measurement tools
- 15.1 General
- 15.2 Adding/removing measurement tools
- 15.3 Editing user presets
- 15.4 Moving and resizing a measurement tool
- 15.5 Changing the measurement parameters
- 15.6 Displaying values in the result table and displaying a graph
- 15.7 Creating and setting up a difference calculation
- 15.8 Setting a measurement alarm
- 16 Working with color alarms and isotherms
- 17 Annotating images
- 18 Programming the camera (time-lapse)
- 19 Recording video clips
- 20 Screening alarm
- 21 Pairing Bluetooth devices
- 22 Configuring Wi-Fi
- 23 Fetching data from external FLIR meters
- 24 Changing settings
- 25 Cleaning the camera
- 26 Technical data
- 26.1 Online field-of-view calculator
- 26.2 Note about technical data
- 26.3 Note about authoritative versions
- 26.4 FLIR E75 24°
- 26.5 FLIR E75 42°
- 26.6 FLIR E75 24° + 14°
- 26.7 FLIR E75 24° + 42°
- 26.8 FLIR E75 24° + 14° & 42°
- 26.9 FLIR E85 24°
- 26.10 FLIR E85 42°
- 26.11 FLIR E85 24° + 14°
- 26.12 FLIR E85 24° + 42°
- 26.13 FLIR E85 24° + 14° & 42°
- 26.14 FLIR E95 24°
- 26.15 FLIR E95 42°
- 26.16 FLIR E95 24° + 14°
- 26.17 FLIR E95 24° + 42°
- 26.18 FLIR E95 24° + 14° & 42°
- 27 Mechanical drawings
- 28 Application examples
- 29 About FLIR Systems
- 30 Definitions and laws
- 31 Thermographic measurement techniques
- 32 About calibration
- 32.1 Introduction
- 32.2 Definition—what is calibration?
- 32.3 Camera calibration at FLIR Systems
- 32.4 The differences between a calibration performed by a user and that performed directly at FLIR Systems
- 32.5 Calibration verification and adjustment
- 32.6 Non-uniformity correction
- 32.7 Thermal image adjustment (thermal tuning)
- 33 History of infrared technology
- 34 Theory of thermography
- 35 The measurement formula
- 36 Emissivity tables
Quick start guide
5
5.1 Procedure
Follow this procedure:
1. Put a battery into the battery compartment.
2. Connect the USB battery charger to the USB connector at the top of the camera.
3. Charge the battery for 2 hours before starting the camera for the first time.
4. Insert a memory card into the card slot at the top of the camera.
Note Only use a memory card that has not previously been used in another type of
camera. The cameras may organize files differently on the memory card. There is
therefore a risk of losing data if the same memory card is used in different types of
cameras.
5. Push the on/off button
to turn on the camera.
6. Aim the camera toward the object of interest.
7. Adjust the infrared camera focus by rotating the focus ring.
Note It is very important to adjust the focus correctly. Incorrect focus adjustment af-
fects how the image modes work. It also affects the temperature measurement.
8. Pull the trigger to save an image.
9. Download and install FLIR Tools/Tools+ or FLIR Report Studio on your computer.
10. Start FLIR Tools/Tools+ or FLIR Report Studio.
11. Connect the camera to the computer using the USB cable.
12. Import the images into FLIR Tools/Tools+ or FLIR Report Studio and create an in-
spection report.
13. Send the inspection report to your client.
5.2 To keep in mind
• Adjust the focus first. When the camera is out of focus, the measurement will be
wrong.
• By default, most cameras adapt the scale automatically. Use this mode first, but do
not hesitate to set the scale manually.
• A thermal camera has a resolution limit. This depends on the size of the detector, the
lens, and the distance to the target. Use the center of the spot tool as a guide to the
minimum possible object size, and get closer if necessary. Make sure to stay away
from dangerous areas and live electrical components.
• Be careful when holding the camera perpendicular to the target. Be observant of re-
flections, especially at low emissivities—you, the camera, or the surroundings may be-
come the main source of reflection.
• Select a zone of high emissivity, e.g., an area with a matte surface, to perform a
measurement.
• Blank objects, i.e., those with low emissivities, may appear warm or cold in the cam-
era, because they mainly reflect the environment.
• Avoid direct sunlight on the details that you are inspecting.
• Various types of faults, e.g., those in a building’s construction, may result in the same
type of thermal pattern.
• Correctly analyzing an infrared image requires professional knowledge about the
application.
#T810190; r. AB/39747/39747; en-US