7 Technical specifications
APO quiescent current 50 µA maximum
Measurement type True RMS, crest factor ≤ 3 at full
scale up to 500 V, decreasing linearly
to ≤ 1.5 at 1000 V
Over-current protection
• mA, μA ranges; 0.5 A/1000 V ce-
ramic fast-blow fuse
• Ampere range; 10 A/1000 V ce-
ramic fast-blow fuse
Continuity test Visual and audible (85 dBA)
Other indications Low battery, over-range, memory
Internal memory 9 storage locations
Operating temperature –10 to 50°C (14 to 122°F)
Storage temperature –30 to 60°C (–14 to 140°F)
Operating humidity Maximum 90% up to 35°C (95°F),
decreasing linearly to 60% at (45°C)
113°F
Storage humidity
90% maximum
Dimensions 207 mm × 98 mm × 63 mm (8.15″ ×
3.9″ × 2.5″)
Weight 0.55 kg (1.22 lb), including batteries
Agency approvals FCC Class B, CE, UL/CSA, GSA, S-
JQA
7.2 Electrical range specifications
Note
Accuracy is stated at 18–28°C (65–83°F) and less than 75% relative humidity.