1.4 Camera Specifications
DH-390 2MP
Camera Platform Type Dome
Array Format Native 320 × 120, 960 × 360 VividIR
Detector Type Long-Life, Uncooled VOx Microbolometer
Pixel Pitch 12 µm
Thermal Sensitivity <50 mK
Spectral Range 8 µm to 14 µm
Lens Athermalized, focus-free; f/1.1
Optical FoV 2X 57° × 40°, Stitched 102° × 40°
Thermal Video Controls for Brightness, Contrast, Colorization, and MSX video overlay
Thermal AGC Region of
In
ter
est (ROI)
Default, Presets and User definable to ensure thermal viewing quality in
regions of interest
Image Uniformity
Optimiza
tion
Automatic Flat Field Correction (FFC
) - Thermal and Temporal Triggers
Camera Model
Thermal
Sens
or
Specifications
Visible Light
Camera
Specifications
Sensor Type 1920 × 1080, 2.1 MP, 1/2.8”
Lens Type 3-9 mm, f/1.6, P-Iris
Frame Rate 30 FPS
Optical FoV 95° × 53°
Aspect Ratio 16:9
White Balance Automatic
Back Light Compensation Ye s
Day Night Mode Automatic with white light and NIR
PAL/NTSC Environm ent
Select either 50 Hz (PAL) or 60 Hz (NT
S
C) shutter timing to match indoor
lighting frequency in order to reduce flicker.
System
Integration
Ethernet 10/100 Mbps
Control Interfaces
Nexus SDK for comprehensive system control and integration; Nexus
CGI fo
r http command interfaces; ONVIF
External Analytics
Comp
atible
Ye s
Measurement
and Analysis
Video Compression Independent channels of streaming H.264 or M-JPEG
Analytics Features
Region Entrance/Intrusion Detection, Crossover/Fence Trespassing;
Auto/Manual Depth Setup, Human and Vehicle Rules, Hand-off target to
autonomous PTZ tracking, Tampering Detection
Analytics Management
Web-based configuration and management, Masking of detection areas,
adj