7 Technical specifications
Ranges 100.00–1000 V
Resolution 0.01 V
Basic accuracy ±(0.7% + 2 digits)
Input impedance 3.5 MΩ
Overload protection 1000 V RMS
AC+DC V
Ranges 100.00–1000 V
Resolution 0.01 V
Basic accuracy ±(1.0% + 5 digits)
Input impedance 3.5 MΩ
Overload protection 1000 V RMS
Watts
Ranges 10–600 kW
Resolution 1 W
Basic accuracy ±(2.5% + 5 digits)
Power factor
Ranges –1.00 to 1.00
Resolution 0.01
Basic accuracy ±3°
Total harmonic distortion
Ranges 0.1%~100.0%
Resolution 0.1%
Basic accuracy ±(3.0% + 10 digits)
Harmonics
Ranges 0.1–100.0%