User Manual

5 Operation
4. One of the following results is displayed:
OLU flashes if the voltage is >1000 V.
LoU flashes if the voltage is <30 V.
outF flashes if the frequency is >65 Hz or <45 Hz.
If normal, L1 flashes for about 3 seconds. Then L2 is displayed.
5. Move the red test lead to the presumed phase line 2.
6. One of the following results is displayed:
123 indicates clockwise or forward rotation, which means that the pre-
sumed phase line 1 is ahead of the presumed phase line 2.
321 indicates counterclockwise or reversed rotation, which means that
the presumed phase line 2 is ahead of the presumed phase line 1.
- - - means that the meter is unable to determine the results.
5.7 Resistance measurements
WARNING
Do not do diode, resistance or continuity tests before you have removed the
power from the capacitors and from a device during a test. Injury to persons
can occur.
1. Set the function switch to the
position.
2. Ensure that the meter is set to resistance measurement. If the
or the
indicator is displayed, press the button repeatedly until none of these
indicators are displayed.
3. Insert the black probe lead into the negative COM terminal and the red probe
lead into the positive terminal.
4. Touch the tips of the probe across the circuit or component under test.
5. Read the resistance value on the display.
5.8 Capacitance measurements
WARNING
Do not do diode, resistance or continuity tests before you have removed the
power from the capacitors and from a device during a test. Injury to persons
can occur.
#T559825; r.8008/8011; en-US 22