User Manual
Table Of Contents
5 Operation
5.5.3 Extended functionality
In addition to the basic voltage and current measurements, the meter can be set
to different modes for extended functionality.
5.5.3.1 Selecting the mode
The mode icons applicable for the selected measurement type are displayed in
the lower part of the display. When a mode is enabled, the icon is framed.
Figure 5.2 Mode icons (AC voltage measurements): Peak mode and Silent
mode are enabled
The navigation buttons are used to select a mode icon and to enable/disable a
mode:
• Use the
and navigation buttons to navigate to a mode icon. The cur-
rently selected icon will flash.
• Press the
button to enable/disable the selected (flashing) mode.
5.5.3.2 Peak mode
In Peak mode, the meter captures and displays the positive and negative peak
values, and updates only when a higher/lower value is registered. Peak mode is
available when measuring AC current or voltage in Manual select mode.
1. Use the navigation buttons to select
and enable Peak mode.
2. Press the
button to toggle between the display of Peak Max and Peak
Min.
• In Peak Max mode, the
indicator is displayed.
• In Peak Min mode, the
indicator is displayed.
3. Press and hold the
button to disable Peak mode.
#T559825; r.8008/8011; en-US 15