7 Technical specifications
Other indications Low battery, over-range, IR, memory
Operating temperature –10 to 50℃ (14 to 122℉)
Storage temperature –25 to 60℃ (–14 to 140℉)
Operating humidity Maximum 90% up to 35℃ (95℉) de-
creasing linearly to 60% at 45℃
(113℉)
Storage humidity
90% maximum
Dimensions 257 mm × 110 mm × 50 mm (10.1″ ×
4.3″ × 2.0″)
Weight 0.63 kg (1.4 lb.)
Bluetooth range 10m (32ft) maximum
Safety Category Rating CAT IV-600V, CAT III-1000V
7.2 Electrical range specifications
Valid for ambient temperature conditions 18 to 28 ℃ (64.4 to 82.4 ℉)
Function Range Resolution Accuracy (of
reading)
AC current 400.0 A 0.1 A ±(2.5% + 8
digits)
1000 A 1 A ±(2.8% + 5
digits)
DC current
400.0 A 0.1 A ±(2.5% + 5
digits)
1000 A 1 A ±(2.8% + 5
digits)
#T559826; r.9072/9080; en-US 25