Owner's manual

MCS-08 Technical Manual, Rev. 1.04 December 2012 Page 26 of 52
Address
R/W
Word
Command
Description
41001
R
1
System Status of
MCS-08AD and
MCS-08DP
D10
00: No module found at address [5]
D11
01: Module at address [5] is active
D12
00: No module found at address [6]
D13
01: Module at address [6] is active
D14
00: No module found at address [7]
D15
01: Module at address [7] is active
41002
R
1
System Status of
MCS-08IO
D0
IO [0]
00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved
D1
D2
IO [1]
00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved
D3
D4
IO [2]
00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved
D5
D6
IO [3]
00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved
D7
D8
IO [4]
00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved
D9
D10
IO [5]
00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved
D11
D12
IO [6]
00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved
D13
D14
IO [7]
00 = Module at address [0] not found
01 = Module at address [0] is active
10 = reserved
11 = reserved
D15
41003
R
1
Status of
MCS-08MB
Gateway
D0
System failure
D1
EEPROM failure
D2
External bus communication error
D3
A module was installed / removed
D4
No module found within the system
D5…D15
Not in use
41004
1
Not in use
41005
R
1
Status of
MCS-08AD [0]
D0
0 System Ready
1 System Busy
D1
0 Error
1 Data ok
D2
0 Weight Stable
1 Weight unstable
D3
0 Gross Mode
1 Net mode
D4
0
Not used
D5
0 Weight / Force
1 Count Mode
D6…D11
Not in use
D12
0 Out of zero range
1 Weight is in zero range
D13
D14
D15
Error Code
0
No Errors
1
ADC out of range
2
ADC over range
3
ADC under range
4
System error
5
In setup mode
6
Low/High voltage det.