Manual
LDU 78.1 Technical Manual, Rev. 12 May 2011
Page 13 of 36
Command Short description Parameter value Page
SL
Auto-transmit: Send Data String „Average/Gross/Status“ continuously None 24
SN
Auto-transmit: Send Net Value continuously None
24
S0/S1
Setpoints: Setup of Setpoints S0 and S1 -99999...+99999 d 26
SR
Reset Firmware (Warm Start) None
14
SS
Save the Setpoint Data (S0, S1, H0, H1, A0 and A1) to the EEPROM None 28
ST
Scale function: Set Tare and Switch to Net Indication None
21
SW
Auto-transmit: Send Data String „Net/Gross/Status“ continuously None
24
SX
Auto-transmit: Send ADC Sample Value continuously None
24
SZ
Scale function: System Zero Point None 21
TD
Communication: Transmission delay 0…255 ms 27
TE
Trigger function: Trigger on Rising Edge (1) or Falling Edge (0) 0 or 1 29
TI
Trigger function: Averaging Time for Automatic Taring 0...65535 ms 32
TL
Trigger function: Trigger Level 0...99999 d 30
TM
Calibration: Tare mode 0 or 1 17
TR
Trigger function: Software Trigger None 29
TS
Trigger function: Stop Value for Re-trigger Function 0...65535 d 31
TT
Trigger function: Averaging Time for Re-trigger Function 0...500 ms 31
TW
Trigger function: Window for Automatic Taring 0...65535 d 31
UR
Digital filter: Update Rate 0, 1, 2...7 20
WP
Save the Setup Data (FL, NR, NT, AD, BR, DX) to the EEPROM None 28
WT
Calibration: Warm-up Time Delay 0...65535 s 17
ZA
Scale function: Set System Zero Point using TI setting None 21
ZI
Calibration: Initial Zero Range 0...99999 d 17
ZR
Calibration: Zero Range 0...99999 d 17
ZT
Zero Tracking: Disable (0) or Enable (1) 0 or 1 16