Function
Description
Regist Register the current weight value – Format 1
Return value Value range
Format: string, 16 digits:
“rrrrrr nnnnnnn dd w” with
rrrrrr Record no., 6 digits 000001, 000002, 000003...
nnnnnnn
Weight value including
decimal point, 7 digits
0...800 000
dd Weight unit, 2 digits g, kg, t, lb
w Scale no., 1 digit 1 (scale 1); 2 (scale 2); 3 (dual scale)
Hint: Unused places within the weight value will be filled with spaces.
Attention: In legal for trade operation an entry to the alibi memory will be created and the
record counter will be incremented by one.
If a recording is not possible, a 2-digit error code will be notified:
E1 Scale in motion E4 No zero crossing
E2 Weight value ≤ 0 E5 Open input (tilt)
E3 Gros weight < minimum load E6 Overload, etc.
Regist2 Register the current weight value – Format 2
Return value Value range
Format: string, 30 digits:
“w_rrrrrr_nnnnnnn_kk_tttttt_dd“ with
w Scale no., 1 digit 1 (cae 1); 2 (scale 2); 3 (dual scale)
rrrrrr Record no., 6 digits 000001, 000002, 000003...
nnnnnnn
Weight value including
decimal point, 7 digits
0...800 000
kk Tare indication
„ “ (no tare); „ T“ (normal tare);
„PT“ (manual tare entry)
ttttttt
Tare value including
decimal point, 7 digits
0...800 000
dd Weight unit, 2 digits g, kg, t, lb
Hint: Unused places within the weight value will be filled with spaces.
Attention: In legal for trade operation an entry to the alibi memory will be created and the
record counter will be incremented by one.
If a recording is not possible, a 2-digit error code will be notified:
E1 Scale in motion E4 No zero crossing
E2 Weight value ≤ 0 E5 Open input (tilt)
E3 Gros weight < minimum load E6 Overload, etc.
Param(w) Read scale parameters
Parameter Type Use
w Integer w = 1 (scale 1); w = 2 (scale 2); w = 3 (dual scale)
Return value Value range
Format: string, 17 digits:
"w_t_z1_z2_z3_k_dd" with
w Scale no., 1 digit 1 (scale 1); 2 (scale 2); 3 (dual scale)
t Scale type, 1 digit 1 (single-interval), 2 (multi-range), 3 (multi-interval)
z1 Scale interval 1, 2 digits 01, 02, 05, 10, 20, 50
z2 Scale interval 2, 2 digits 02, 05, 10, 20, 50 (at single-interval: 01)
Z3 Scale interval 3, 2 digits 05, 10, 20, 50 (at single-interval: 01)
k Decimal places, 1 digit 1, 2, 3, 4, 5
dd Weight unit, 2 digits g, kg, t, lb