Instruction Manual

FLINTEC
Document
Date
Code
Rev.
Page
FAD - 4 DIGITAL LOADCELL JUNCTION BOX
02.05.00
FAD4_2RM
2
5 of 20
3 FUNCTIONAL DESCRIPTION
All FAD-4 operations are performed via the serial interface, through the use of LESIP Master/Slave serial
interface protocol . The communication standards and timing are described in the LESIP manual. The file types
specific to FAD-4 will be described here. The FAD-4 is always a slave. In principle a number of FAD`s
may be connected in a network microprocessor controlled device.
The communication buffer size is 13 bytes max for Transmitter and Receiver (Half duplex).
Detailed description of the file types and sequences is given in the following pages .
LIST OF FILE TYPES (COMMANDS)
TYPE HEX DESCRIPTION TIME RESPONSE
? 3F UPLOAD WEIGHT & STATUS 50 ms STATUS + WEIGHT
A 41
DEADLOAD CAL (ELECTRONIC mV/V)
1.5 sec Poll slave by using command ‘?’
a 61 DEADLOAD CAL(weights) 16 sec Poll slave by using command ‘?’
B 42 SPAN CAL (ELECTRONIC, mV/V input) 1.5 sec Poll slave by using command ‘?’
b 62 SPAN CAL (weights) 16 sec Poll slave by using command ‘?’
C 43 DOWNLOAD mV/V for each corner 0.1 sec Poll slave by using command ‘?’
c 63 CALIBRATE CORNERS 16 sec Poll slave by using command ‘?’
d 64 UPLOAD AUDIT TRAIL CNT,CALLOCK 0.1sec 6 Digit counter, status Callock
f 66 UPLOAD CORNER FACTORS 0.1 sec FACTOR 1,2,3 ,4
G 47 GROSS 0.1sec NONE
H 48 RESERVED
i 69 UPLOAD INTERNAL RESOLUTION 0.1 sec INTERNAL DIVIDIONS
J 4A LOCK / UNLOCK CALIBRATION 0.1sec 6 Digit PIN or NAK
P 50 DOWNLOAD PAR 1/ PAR 2/ PAR 3 0.1 sec ACK or NAK
p 70 UPLOAD PAR 1/ PAR 2/ PAR 3 0.1 sec PAR 1/2/3
Q 51 DOWNLOAD SETPOINT 1 / SETPOINT 2 0.1 sec ACK or NAK
q 71 UPLOAD SETPOINT 1 / SETPOINT 2 0.1 sec SETPOINT 1/ SETPOINT 2
R 52 RESET SLAVE 16 sec NONE
S 53 DOWNLOAD SETUP : SETUP 1 / SETUP
2
0.1 sec ACK or NAK
s 73 UPLOAD SETUP1 0.1sec Setup1
T 54 TARE 0.1 sec NONE
W 57 WRITE TO EEPROM 16 sec NONE
Z 5A ZERO 3 sec NONE