Instruction and Operation Manual for ATEX Approved Load Cells Table of contents 0. Valid for Load Cells 2 1 . Preamble 2 2 . Equipment Function 2 2.1 Details 2 2.2 Connection of the Standard Version 2 2.2.1 Examples of suitable circuits with approved safety barriers : 3 2.3 Connections of the 6-wire Version 3 2.4 Advice for Interconnections 4 2.5 Coding of the Load Cells 4 2.6 Reference notes concerning electrostatics 4 2.
Instruction and Operation Manual for ATEX Approved Load Cells 0. Valid for Load Cells BK2, PC1, PC2, PC2H, PC6, PC12, PC22, PC42, PC46, PC60, PCB, SB2, SB4, SB5, SB6, SB8, SB14, SLB, ZLB, RC1, RC2, RC3, UB1, UB5, UB6, ULB 1 . Preamble This manual covers only the “Ex” relevant aspects. 2 . Equipment Function Flintec load cells are designed to be used in various kinds of industrial scales and meet the most stringent accuracy requirements.
Instruction and Operation Manual for ATEX Approved Load Cells 2.2.1 Examples of suitable circuits with approved safety barriers : Warning: Example : The displayed examples are verified for ignition protection. The specialist who installs the equipment must take responsibility for proper operation in combination with various measuring equipment . With safety barriers for single-ended supply Wiring diagrams of different circuit examples are available on request 2.
Instruction and Operation Manual for ATEX Approved Load Cells 2.4 Advice for Interconnections a) Follow and respect the formation-regulations of the application-country. E.g. in Germany follow the regulations EN 60079-14 and EN 61241-14. b) It is ONLY permitted to use approved safety barriers or switch amplifiers for explosive-areas. In Europe, it is a requirement to have an EC-Type Examination Certificate from a nominated certifying body for the Zones 0 / 1 / 20 / 21.
Instruction and Operation Manual for ATEX Approved Load Cells 2.7 Special notes to the relative inductance and capacities of cables within intrinsically safe circuits Up to a cable length of 10 meters, the inductance and capacitance of the load cell cables are negligible. The cable lenght is shown as ZZ within the type code. In case the load cell cable lenght exceeds 10 meter, the inductance and capacitance have to be considered. Following default values can be used (according article 12.2.2.
Instruction and Operation Manual for ATEX Approved Load Cells 4. Commissioning and Installation a) This equipment (load cells) can be used either in zone 0, 1 or 2, or zone 20, 21 or 22 in explosion groups IIA, IIB, IIC, IIIA, IIIB, or IIIC. b) The allowed ambient temperature range is –40°C to 45°C/60°C. c) This equipment complies to protection class > IP67 / EN 60529. d) This equipment must be electro statically grounded. e) The load cell must not be used if it is defective or shows any visible damage.
Instruction and Operation Manual for ATEX Approved Load Cells EC-Declaration of Conformity 9. EC-Declaration of conformity of a sub-assembly with the ATEX-Directive 94/9/EC (ATEX95), Amendment X.
Instruction and Operation Manual for ATEX Approved Load Cells 10. EC- Type Examination Certificate Last revision: 24.10.2014 Revision: 9.5 Page 8 / 12 Date of 1st issue: 03.06.
Instruction and Operation Manual for ATEX Approved Load Cells Last revision: 24.10.2014 Revision: 9.5 Page 9 / 12 Date of 1st issue: 03.06.
Instruction and Operation Manual for ATEX Approved Load Cells Last revision: 24.10.2014 Revision: 9.5 Page 10 / 12 Date of 1st issue: 03.06.
Instruction and Operation Manual for ATEX Approved Load Cells Last revision: 24.10.2014 Revision: 9.5 Page 11 / 12 Date of 1st issue: 03.06.
Instruction and Operation Manual for ATEX Approved Load Cells Last revision: 24.10.2014 Revision: 9.5 Page 12 / 12 Date of 1st issue: 03.06.