Manual
2
PRODUCT SPECIFICATIONS
SAFETY INFORMATION
DANGER:
1. Always disconnect power source before performing any
work on or near the motor or its connected load. If the
power disconnect point is out-of-sight, lock it in the open
position and tag it to prevent unexpected application of
power. Failure to do so could result in fatal electrical
shock.
2. Do not handle the pump with wet hands or when
standing in water as fatal electrical shock could occur.
Disconnect main power before handling unit for ANY
REASON!
3. RISK OF ELECTRIC SHOCK. These pumps have not
been investigated for use in swimming pool areas.
WARNING:
1. Follow all local electrical and safety codes, as well
as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA).
2. Replace damaged or worn wiring cord immediately.
3. Do not kink power cable and never allow the cable
to come in contact with oil, grease, hot surfaces, or
chemicals.
4. Wire motor to correct supply voltage - see motor
nameplate and wiring diagrams and check voltage of
power supply.
5. Unit must be securely and adequately electrically
grounded. This can be accomplished by wiring the unit
to a ground metal-clad raceway system or by using a
separate ground wire connected to the bare metal of the
motor frame or other suitable means.
6. This product contains chemicals known to the State of
California to cause cancer and birth defects or other
reproductive harm.
7. Hazardous Pressure! Install pressure relief valve in
discharge pipe. Release all pressure on system before
working on any component.
8. Do not use to pump ammable or explosive uids
such as gasoline, fuel oil, kerosene, etc. Do not use in
ammable and/or explosive atmospheres.
CAUTION:
1. Protect the power cable from coming in contact with
sharp objects.
2. Be careful when touching the exterior of an operating
motor - It may be hot enough to be painful or cause
injury.
3. Make certain that the power source conforms to the
requirements of your equipment.
4. Do not run pump dry.
5. Pump and plumbing must be full of water before startup.
6. Do not pump water which contains sand, mud, silt, or
debris
NOTE: Pumps with the “UL” Mark and pumps with the
“US” mark are tested to UL Standard UL778.CSA certied
pumps are certied to CSA Standard C22.2 No. 108. (CUS)
“CPJ” Series Pump & Motor Specications Chart 1
Pump
Model
No.
HP
Motor
Voltage
Motor
Wired
For
Motor Max. Amps Pressure
Switch
Setting
PSI
Tapping Size (inches)
115V 230V Discharge Suction Pressure
CPJ03SB 1/3 115/230* 115 8.6 4.3 30-50 3/4 1-1/4 -
CPJ05B 1/2 115/230* 115 13 6.5 30-50 3/4 1-1/4 1
CPJ05SB 1/2 115/230* 115 13 6.5 30-50 3/4 1-1/4 -
CPJ07B 3/4 115/230* 230 14 7 30-50 1 1-1/4 1
CPJ07SB 3/4 115/230* 230 14 7 30-50 1 1-1/4 -
CPJ10B 1 115/230* 230 18 9 30-50 1 1-1/4 1
CPJ10SB 1 115/230* 230 18 9 30-50 1 1-1/4 -
CPJ15B 1-1/2 115/230* 230 21 10.5 30-50 1 1-1/4 1
CPJ15SB 1-1/2 115/230* 230 21 10.5 30-50 1 1-1/4 -
All motors are single phase, 60 Hz., 3450 RPM.
Motors marked with * are dual voltage and can be changed to either 115V or 230V by following the wiring diagram on
motor decal.