4. Install a 3/4 in. union (optional) and continue with
pipe and 3/4 in. x 3/4 in. x 3/4 in. tee. (Fig. 4)
3. Attach a 1 in. slip (glue) x 3/4 in. FPT adapter and
3/4 in. MPT x 3/4 in. slip. (Fig. 3)
Glue
Adapter
Coupling
3
IL1368
Glue
Tee
Union
4
5. Make the connection to the house plumbing. From the
tee, install pipe and shut off valve (optional). (Fig 5)
IL1386
6
6. Completed installation with piping and tank is shown
(Fig. 6)
IL1369
Glue
To House
Plumbing
From Pump
Shut off valve
5
TANK TO HOUSE CONNECTION