Owner manual

FILL IN FOR FUTURE REFERENCE
MODEL NO:___________________________________________
DATE INSTALLED:______________________________________
DEALER:______________________________________________
INSTALLATION, OPERATION, AND
MAINTENANCE MANUAL
CBW10, CBW10D, CBW20, CBW20D
CCF10, CCF10D, CCF20, CCF20D
(Addendum Included)
AUTOMATIC WATER
FILTERS
PP0131
0611
Supersedes
0610
SPECIFICATION TABLE
Units
CBW10,
CBW10D
CCF10,
CCF10D
CBW20,
CBW20D
CCF20,
CCF20D
Service Flow
(1)
Cont. GPM 3 3 5 5
Peak GPM 8 8 10 10
Pipe Size In/Out - Inches 1” 1” 1” 1”
Operating Pressure Range PSI 30 - 125 30 - 125 30 - 125 30 - 125
Max Operating Temperature Degrees F 110 110 110 110
Mineral Tank Size (Dia. x Ht.)
(2)
Inches 10 x 44 10 x 44 12 x 52 12 x 52
Shipping Weight Lbs. 47.5 137 57.5 235
Overall Height Inches 52 52 60 60
Drain Flow During Regeneration
(3)
GPM 5.3 6.5 7.5 7.5
NOTE:
(1)
Pressure drop not to exceed 15 psi.
(2)
Product materials and workmanship are protected with a written warranty.
(3)
Untreated water provided during all steps of regeneration.
023367