2. Remove the cover from the control box and
mount it in an indoor location protected from
moisture. 

4. Attach the black, yellow and red wires to the
appropriate terminals marked “B”, “Y” and “R”.

5. Connect the green ground wire from the pump to
the green ground screw in the lower right corner
of the control box.

3. Thread the electrical wire from pump into the
right opening in the bottom of the control box
and tighten the electric wire strain relief securely.

L1 L2 R Y B
Terminal
L2
Terminal
R
Terminal
Y
Terminal
B
Green
Ground
Screw
Terminal
L1
Green
Ground
Screw
2
L1 L2 R Y B
IL1176
L1 L2 R Y B
IL1175
4
5
L1 L2 R Y B
IL1174
L1 L2 R Y B
IL1177
L1 L2 R Y B
IL1178
L1 L2 R Y B
IL1179
L1 L2 R Y B
IL1180
9. Remove cover from pressure switch and screw
the switch into the 1/4 in. opening on the top of
the pipe tee. 
6. Thread the electrical wire from the pressure
switch into the left opening at the bottom of the
control box and tighten the electric wire strain
relief securely. 
7. Connect the two wires from the pressure switch
to the terminals in the control box marked L1 and
L2. 
8. Connect the green ground wire from the pressure
switch to the green ground screw in the lower left
corner of the control box and re-install the control
box cover. 