Page 11
Setting up the sensor
Position
The sensor must be placed between 2.4 to 4 meters (8 to 14 ft.) behind the
tee.
Ground Surface
The sensor should be used on a level surface, (grass, carpet, or hard floor).
Handle
CAUTION
The handle is locked in position by spring loaded
plungers. Release the plungers before moving
the handle. Do not force the handle while locked.
Release the handle by sliding the two thumb sliders inwards to release the
spring loaded pins that lock the handle position. At the same time pull the
handle backwards.
When free, move the handle to the “down” position. The spring loaded pins
will again lock the handle in the down position.
In the down position, the handle acts as the rear support for the sensor.
Leveling
The sensor should be set up with no roll (sideways angle) and tilted at the
optimum angle of approximately 10 degrees (leaning backwards).
The X2C model has a built-in automatic leveling mechanism that will adjust
the sensor to the correct roll and tilt angles for operation.
Other X2 models do not have automatic leveling: in this case the sensor roll
and tilt angles must be set manually by adjusting the feet of the sensor
and/or by modifying the work surface to achieve the correct sensor angles.