User's Manual

CAUTION
Take precautions to prevent the
sensor from being struck by a
ball. For example, place the
sensor behind a screen or erect
a non-metallic deflector in front
of the sensor for protection.
Choose a position for the
sensor. It must be set back
between 20 and 60 ft. behind
the home plate, and laterally
offset within the corresponding
minimum and maximum bounds
illustrated in the adjacent
figure. The lateral offset is
needed to avoid players
blocking the sensor’s view of
the ball.
The sensor can be mounted on
a vertical or horizontal pole
structure using the pole mount
bracket or on a heavy duty
tripod (not supplied).
The sensor must aim at the top
of the pitcher’s mound.
The height of the sensor must
be between 6 and 16 feet
depending on its distance
behind the home plate, as
shown in the diagram.
NOTE
Take care that the sensor does
not block spectators view, if
applicable.