SDS
PerformanceProAdhesives.com Page 4 of 6
Safety Data Sheet
ADVANCED HYBRID ADHESIVE
PERFORMANCE PRO
General Information: Data derived for the product as a whole are of higher priority than data for single ingredients.
Acute Toxicity
Product Details:
Route Of Exposure Result/Effect Species/Test System Source
Oral LD50:>2000 mg/kg Rat Conclusion by analogy
Dermal LD50:>2000 mg/kg Rat Conclusion by analogy
Skin Corrosion / Irritation
Assessment:
Based on the available data a clinically relevant skin irritation hazard is not expected. Temporary symptoms of an irritation cannot be excluded if the
adhesive product is removed mechanically after contact.
Product Details:
Route Of Exposure Result/Effect Species/Test System Source
Not irritating Rabbit Conclusion by analogy
Serious Eye Damage / Eye Irritation
Assessment:
Based on the available data a clinically relevant eye irritation hazard is not expected. Temporary symptoms of an irritation cannot be excluded if the
adhesive product is removed mechanically after contact.
Product Details:
Route Of Exposure Result/Effect Species/Test System Source
Not irritating Rabbit Conclusion by analogy
Respiratory Or Skin Sensitization
Product Details:
Route Of Exposure Result/Effect Species/Test System Source
Dermal Not sensitizing Guinea-pig; Buhler Conclusion by analogy
OECD 406
Germ Cell Mutagenicity
Assessment: For this endpoint no toxicological test data is available for the whole product.
Carcinogenicity
Assessment: For this endpoint no toxicological test data is available for the whole product.
Reproductive Toxicity
Assessment: For this endpoint no toxicological test data is available for the whole product.
Specific Target Organ Toxicity (Single Exposure)
Assessment: For this endpoint no toxicological test data is available for the whole product.
Specific Target Organ Toxicity (Repeated Exposure)
Assessment: For this endpoint no toxicological test data is available for the whole product.
Aspiration Hazard
Assessment: Based on the physical – chemical properties of the product no aspiration hazard must be expected.
Further Toxicological Information
Quartz has been classified by IARC as carcinogen group 1 (“carcinogen to humans”) and by NTP as known to be human carcinogen. No component of
this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by OSHA.
Data Related To Ingredients:
Product Of Hydrolysis (Methanol)
Methanol (CAS 67-56-1) is readily and rapidly absorbed at all exposure routes and is toxic by all routes. Methanol may cause irritation of the mucosa, as
well as nausea, vomiting, headaches, vertigo and visual orders, including blindness (irreversible damage to the optic nerve), acidosis, spasms, narcosis
and coma. There may be a delay in the onset of these effects after exposure.
11. Toxicological Information