User Manual
Installation and adjustment
Created by EBCCW 00:06
43
5112204
5.4 Test run
The purpose is to check functionality. Testing is performed by running man-
ually with an empty elevator without products.
Adjustment for making the lift cage stop exactly in horizontal line with con-
necting tracks is performed in a later stage.
Action Remark
Manual mode check Elevator can be set to manual mode enabling
vertical motion up/down.
Vertical motion and end
positions
Run elevator carefully towards end-position.
Listen for noise and vibrations.
a. Check that elevator is running high-speed
outside the low-speed areas.
b. Check ramp-down to low speed while
inside low-speed areas.
c. Check that when stopped in end position,
the stop and low speed sensors are still
activated.
See Adjustment
on
page 53
Limit switch check Disconnect stop position sensors by
unscrewing the sensor cable in the sensor
end.
The elevator will pass the stop sensor. It will
probably loose the low speed sensor which
may cause it to switch to high speed.
Check that limit switch interlocks the
corresponding motion direction.
Re-connect stop position sensors.
See Limit switches
on page 54
Interlocking sensor check Check that if any of these sensors are
activated vertical motion in both directions is
interlocked.
See Adjustment on
page 53