Instruction Manual
PRODUCT DATA SPECIFICATIONS
MADE IN USA
800-969-0108•610-916-9501(Fax)
2670Leiscz’sBridgeRoad,Suite400,Leesport,PA19533
e-mail:flexroof@cs.com•www.flexroofingsystems.com
As with all building materials, it is the responsibility of the installer to review its usage with a design professional to 
confirm safety, compatibility and acceptance with the Flex Membrane roof system as well as local building codes.
Flex Retrofit Drain 
PVC Coated Flange Model
PRODUCT DESCRIPTION
Constructed of aluminum and stainless 
steel components with a large, plastisol 
coated flange for hot air welding of Flex 
Membrane PVC roof membranes. The drain 
flange has a depressed sump area and 
an oversized, low profile strainer dome to 
facilitate the easy drainage of all water 
from the roof surface. The Flex Retrofit 
Drain PVC Coated Flange Model incorpo-
rates the technology of the RAC Backflow 
Compression Seal providing a mechanical 
watertight connection.
FEATURES & BENEFITS
• Pre-punched, .080-in. thick, extra large 
18-in. x 18-in. aluminum drain flange 
with plastisol coating. The coated 
flange, provides ample area for hot 
air welding of Flex Membrane PVC 
membranes, giving a homogeneous 
water tight connection.
• 14-in. diameter .080-in. thick aluminum 
drain strainer dome. 
• 9-in. long drain stem. 
• Incorporates the RAC Backflow 
Compression Seal.
• Simple and easy to install.
APPlICATION
Flex Retrofit Drains are designed to replace 
existing drains in reroofing applications. 
Installed from the roof surface, Flex Retrofit 
Drains are engineered to be installed with-
out removing the existing plumbing or fixture 
while providing a watertight connection to 
the roof system and the existing plumbing.
APPROvAlS 
& STANDARDS
ANSI/SPRI RD-1 is a national performance 
standard for retrofit roof drains. While most 
retrofit drains are not tested to this standard, 
the Flex Retrofit Drain PVC Coated Flange 
Model with RAC Backflow Compression Seal 
exceeds the standard, which requires that 
the seal hold a 10-ft. column of water for 24 
hours without leaking. 
IAPMO PS 97-96 – a standard plumbing 
industry test designed to check for leakage 
at connections under a 10 foot head of 
water for a 24 hour period. This test was 
performed by the Smith-Emery Company, 
a nationally recognized independent test 
laboratory providing physical testing of 
construction related materials. The Flex 
Retrofit Drain produced no leakage.
PHYSICAl DATA
The data below is constant for all Flex Retrofit Drain 
PVC Coated Flange Models.
DRAIN BODY SEAL
.080" thick 
aluminum
Watertight RAC Backflow 
Compression Seal requires 
7
/16" wrench
FLANGE STRAINER DOME
18" x 18" 
plastisol coated 
with sump area
14" width, 4" high, made 
of .080" thick aluminum; 
vandal-resistant 
model available
STEM
9" length
ORDERING INFORMATION
CAT. NO. SIzE DOME TYPE PKG
DIMENSIONAL 
WEIGHT
8020 3" Aluminum Each 32 lbs.
8021 4" Aluminum Each 32 lbs.
8022 5" Aluminum Each 32 lbs.
8041 6" Aluminum Each 32 lbs.
RP12104  Rev. 0512