SDS
Version: 1.0
Revision Date: 04/22/2021
SDS_US - RE1000027550
4/17
Notification Procedures:
Prevent entry into waterways, sewer, basements or confined areas. Stop
the flow of material, if this is without risk. ELIMINATE all ignition sources
(no smoking, flares, sparks or flames in immediate area). Stop leak if you
can do so without risk.
Environmental Precautions:
Do not contaminate water sources or sewer. Prevent further leakage or
spillage if safe to do so. Avoid release to the environment.
7. Handling and storage
Precautions for safe handling:
Keep away from heat, hot surfaces, sparks, open flames and other ignition
sources. No smoking. Do not spray on an open flame or other ignition
source. Pressurized container: Do not pierce or burn, even after use. Do
not handle until all safety precautions have been read and understood.
Obtain special instructions before use. Use personal protective equipment
as required. Avoid contact with skin. Wash hands thoroughly after handling.
Conditions for safe storage,
including any
incompatibilities:
Store locked up. Pressurized container: protect from sunlight and do not
expose to temperatures exceeding 50°C. Do not pierce or burn, even after
use. Aerosol Level 3.
8. Exposure controls/personal protection
Control Parameters
Occupational Exposure Limits
Chemical Identity
Type
Exposure Limit Values
Source
Propane, 2-methyl-
REL
800 ppm
1,900 mg/m3
US. NIOSH: Pocket Guide to Chemical Hazards, as
amended (2005)
STEL
1,000 ppm
US. ACGIH Threshold Limit Values, as amended
(03 2018)
Benzene, methyl-
STEL
150 ppm
560 mg/m3
US. OSHA Table Z-1-A (29 CFR 1910.1000), as
amended (1989)
REL
100 ppm
375 mg/m3
US. NIOSH: Pocket Guide to Chemical Hazards, as
amended (2005)
TWA
100 ppm
375 mg/m3
US. OSHA Table Z-1-A (29 CFR 1910.1000), as
amended (1989)
Ceiling
300 ppm
US. OSHA Table Z-2 (29 CFR 1910.1000), as
amended (02 2006)
TWA
20 ppm
US. ACGIH Threshold Limit Values, as amended
(2008)
TWA
200 ppm
US. OSHA Table Z-2 (29 CFR 1910.1000), as
amended (02 2006)
MAX.
CONC
500 ppm
US. OSHA Table Z-2 (29 CFR 1910.1000), as
amended (02 2006)
STEL
150 ppm
560 mg/m3
US. NIOSH: Pocket Guide to Chemical Hazards, as
amended (2005)
Naphtha (petroleum), heavy
alkylate
PEL
100 ppm
400 mg/m3
US. OSHA Table Z-1 Limits for Air Contaminants
(29 CFR 1910.1000), as amended (02 2006)
TWA
100 ppm
400 mg/m3
US. OSHA Table Z-1-A (29 CFR 1910.1000), as
amended (1989)
REL
100 ppm
400 mg/m3
US. NIOSH: Pocket Guide to Chemical Hazards, as
amended (2010)
Distillates (petroleum), light
distillate hydrotreating process,
low-boiling - Mist.
STEL
10 mg/m3
US. NIOSH: Pocket Guide to Chemical Hazards, as
amended (2005)
TWA
5 mg/m3
US. OSHA Table Z-1-A (29 CFR 1910.1000), as
amended (1989)
REL
5 mg/m3
US. NIOSH: Pocket Guide to Chemical Hazards, as
amended (2005)
PEL
5 mg/m3
US. OSHA Table Z-1 Limits for Air Contaminants
(29 CFR 1910.1000), as amended (02 2006)
Titanium oxide (TiO2)
TWA
10 mg/m3
US. ACGIH Threshold Limit Values, as amended
(2008)
Titanium oxide (TiO2) - Total dust.
PEL
15 mg/m3
US. OSHA Table Z-1 Limits for Air Contaminants
(29 CFR 1910.1000), as amended (02 2006)
TWA
10 mg/m3
US. OSHA Table Z-1-A (29 CFR 1910.1000), as
amended (1989)
Titanium oxide (TiO2) - Respirable
fraction.
TWA
5 mg/m3
US. OSHA Table Z-3 (29 CFR 1910.1000), as
amended (03 2016)