Specification Sheet

Model 5600SXT Control Valve
Part No. 42749 7/08
Back without cover
T
Product Features
Large LCD display with 48 hours of internal power
backup capacitor
LCD display alternates between time of day, volume
remaining or days to regeneration, and tank in service
(twin tank systems only)
Compact turbine meter
Downflow or upflow regeneration cycles
Choose from 4 modes of operation: immediate meter
regeneration, delayed meter regeneration, delayed time
clock regeneration or day of week regeneration
Continuous flow rate of 20 GPM
Backwash capacity handles tanks up to 12" diameter for
softener applications, 10" for filter applications
• Double backwash capability
Options
Bypass valve
Softener or filter control valves
Backwash filter
Upflow or downflow regeneration
Meter or day initiated regeneration
Double backwash
Auxiliary switches
Valve Specifications
Valve Material Fiber Reinforced Polymer
Inlet/Outlet 3/4", 1", 1-1/4"
Cycles 5
Flow Rates (50 psi Inlet) - Valve Alone
Continuous (15 psi drop) 20 GPM
Peak (25 psi drop) 26 GPM
CV (flow at 1 psi drop) 5.0
Max. Backwash (25 psi drop) 7 GPM
Regeneration
Downflow/Upflow Both
Adjustable Cycles Yes
Time Available Up to 199 Minutes per Cycle
Meter Information
Meter Accuracy Range .25 - 15 GPM +/- 5%
Meter Capacity Range (gal.) 1 - 60,000
Dimensions
Distributor Pilot .8125" or 1.05" Pipe O.D.
Drain Line 1/2" NPTF
Brine Line 1600 - 3/8"
Mounting Base 2-1/2" - 8 NPSM
Height From Top of Tank 7-1/2"
Typical Applications
Water Softener 6" - 12" Diameter
Iron Filter 6" - 10 " Diameter
Sediment Filter 6" - 10 " Diameter
Carbon Filter 6" - 10 " Diameter
Neutralizing Filter 6" - 10 " Diameter
Additional Information
Injector Brine System 1600
Electrical Rating 24 v, 50 Hz, 60 Hz
Max. VA 8.4
Estimated Shipping Weight
Time Clock: 6 lbs
Metered Valve: 7 lbs.
Pressure
Hydrostatic: 300 psi
Working: 20 - 125 psi
Temperature 34
o
- 110
o
F
Approvals
UL (powerhead only)
UL Recognized Component

Summary of content (1 pages)