Status/Error
conditions
Power on Fusion and verify that no error occurs during
the boot sequence using the LEDs and/or FLARM Hub.
If an error occurs, check the severity and type of error
(error code) to determine the proper remedy.
Verify that FLARM has GPS reception at the latest 15
minutes after power-on. The aircraft/device must be
outside with a clear view of the sky. The system
should indicate GPS and TX (Transmit). In addition,
RX (Receive) should be indicated if other transmitting
FLARM-equipped aircraft are within range.
Verify that connected displays are showing normal
indications.
See the User and Maintenance Manual and the display
manual for details.
13 AMP Verify that the Annual Maintenance has been added
to the AMP or equivalent (see Section 2.9).
14 Range analysis Perform a range analysis after a couple of flights to
verify acceptable range. Omnidirectional range with
external antennas should normally be at least 10 km,
and with internal antennas > 5 km. Acceptable range
is indicated by the range analyzer result graph.
Note: This is formally not part of the
installation/change to the type certificate and
the Certificate of Release to Service (CRS)
may be issued before the range analysis has
been completed.
See the User and Maintenance Manual for details.