Verifying the proper installation of the cabinet must be done before the installation can be
considered complete.
Verify that all of the following re quirements are met:
Clearance requirements are met at least 24” front, 12” side, and 24” rear. There must be
room to open the cabinet door s for service.
The base station is powered up. All the LEDs in Table 7 .1 Power On Expec ted LEDs must
reflect the states listed in the table. The system should remain in the powered up state. I f it
is nec essary to power down the base station, do so only in acc ordance with the instructions in
Chapter 8. Powe ring Down the Cabinet .
Correct terminations have bee n m ade on all T1 cables.
No kinks are present in the RF cables.
RF cable m a rkings ma tch those specified in Chapter 6. Connec ting the Antennas.
© 2005 Flarion
Flarion Proprietary and Confidential
Version 1.3
Page 9-1