Powering D own the Cabinet
Cha pter 8. Power ing Down the Ca binet
The base station is powere d down using a PC or terminal connected to the C OM 1 port on the
Master C ontrol Unit (MCU) board. This helps ensure that all system files a re closed before the
power is shut off. Attach the PC or terminal using a serial cable with a null-m odem adapter. T he
PC should be running a te rminal emulation such as Microsoft
®
Windows
®
HyperTerm inal.
Connect the 9–pin fem ale RS-232 connec tor (DB9F) to the COM1 port located on the MC U.
Connect the 9–pin femal e cable connec tor (DB 9F) on the other end of the cable to the connec tor
of the VT- 100 term inal or to the PC serial port. Either COM 1 or COM2 of the PC m ay be used.
The following settings should be use d for Hyper Term inal sessions:
Bits pe r second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
WARNING:
ALL POWER OPERATIONS SHOULD BE PERFORM ED BY QUALIFIED
PERSONNEL O NLY.