Chapter 2: Verifying the Site Preparation
2.2. Preparing the Floo r
A c oncr ete slab at the outdoor base station location must be provided for mounting. Install concrete
anchors in the slab for 3/8” s ize bolts, 1” minimum length. Use corrosion resistant anchors.
Locate the anchors to match the mounting hole pattern of the outdoor ca binet assembly. There are
a total of six (6) clearance holes in the base of the cabinet, one in each corner and two located
centrally. Figure 2-1: Clearance Hole in Base of Cabinet shows the clearance hole in the rea r
right corner of the cabinet near the antenna connections. Figure 2 -2: C learanc e H oles in Cabinet
Base — Bottom View shows the location of all six holes.
Figure 2-1: Clearance Hole in B ase of Cabinet
RadioRouter® Base Station Outdoor I nstallation Guide © 2005 Flarion
Flarion Proprietary and Confidential