Page 26
Procedure 6-1 Connecting the Antenna Cables
1.
If they have not been removed already, remove the side access screw panels using a
tamper resistant insert hex bit. See Figure 3.2 Side Screw Panels.
2.
If they have not been removed already, remove the outer panel and seal inserts of the
Roxtec assembly on the rear of the cabinet. See Figure 4.5 Roxtec Assembly
3.
Route the antenna cable through the rectangular opening in the rear of the cabinet.
4.
Route the cable with the proper bend radius and connect it to the lightning suppressors
shown in Figure 6.3 Antenna Cable Installed.
Figure 6.3 Antenna Cable Installed
5.
Fully seat the connector and hand tighten with an appropriate tool. The cable connector nut
is 1 1/4” hex across flats.
6.
Repeat Step 3 through Step 5 for all antenna cables.