User's Manual

Mounting the Cabinet to the Floor
3.3. Mounting the Cabinet to th e Flo or
Once the c abinet has been moved to its final location, it must be bolted to the floor.
Note:
Reinstallation of the rear panel is optional. If the rear panel is to be reinstalled, make sure that
there is sufficient rear clearance to reinstall in place or reinstall prior to final positioning of the
cabinet.
1.
Align the clearance holes in the base of the c abinet to the threaded holes in the floor.
Although there are two clearance holes in each corner, only one is nece ssary for mounting.
2.
Screw the cabinet to the floor using 1/2” diameter screws and flat washers.
3.
Tighten the screws to 400 in-lb +/- 25 in-lb.
Note:
Replace the front access panel after all cables have been routed and conne cted.
3.4. Reseating the RF C ards
It is possible that during shipping some settling of the modules in the base station m ay have
occurred. Since this can le ad to le ss than optima l c onnec tivity of the modules, they m ust be
reseated.
© 2005 Flarion
Flarion Proprietary and Confidential
Version 1.7
Page 3-5