User manual
12
Installation
Note: Follow the instructions for the host device.
Avoid damp environments and extreme temperatures (Fig. 3). Note that metal
surfaces and walls containing metal can severely dampen or reflect the radio
signals (Fig. 4). Maintain a minimum distance of one metre between the radio
modules (Fig. 5) during installation. Maintain a minimum distance of one metre
from large appliances (Fig. 6).
• Follow the instructions for the host device when determining the installation
location.
• Plug the three-pin terminal of the radio module (Fig. 1.3) onto the underside
of the device (Fig. 2).
• Close the lid of the device. (Special feature of smoke detectors: If a
battery is not inserted into the smoke detector, it is not possible to lock
the smoke detector in place on the radio module.)
Note: Make sure that the connection wires are not routed over
the circuit board of the radio module — instead, they must be
routed directly from the edge of the housing to the three-pin
plug on the radio module
• Once all radio modules/host devices are installed, perform a function
test for example by pressing the test button on the smoke detector until
the smoke detector emits alarm sounds or provoke a false alarm. (When
performing the function test, follow the instructions for the host device.)
The radio modules/or the devices equipped with it of the same radio
group signal the alarm acoustically and automatically return to normal
mode after a short period of time. If a detector forwards the OUT signal,
it acknowledges that it has done so by emitting three short sounds. See
the section entitled „Operation/testing“.
The device is approved for operation inside the European Community.
GEV GmbH hereby declares that this device (Radio Transmit and Receive
Module FMF 3545) accords with the fundamental requirements and the
other relevant regulations of guideline 1999/5EG. The full declaration of
conformity can be seen under: www.gev.de
Recycling guidelines:
This device must not be disposed of as unsorted household waste.
Used devices must be disposed of correctly. Contact your local town
council for more information.
Technical data:
Type designation FMF 3545
Frequency 0 - 868 MHz
Operating voltage 9 V from the host device
Working temperature range 0 - 40°C
Relative humidity 0 - 90% non-condensing
Dimensions Ø 106 mm, height 12 mm
Colour white
Technical and design features may be subject to change.