5.1 Absolute Maximum Rating
Table 9: Absolute Maximum Rating Recommended Operating Conditions
5.2 Recommend operation conditions
Operating Condition Min Typical Max Unit
Storage Temperature -40 -- +85 °C
Operating Temperature Range -20 -- +70 °C
VDD Voltage +3 +3.3 +3.6 V
Table 10: Recommended Operating Conditions
5.3 Power consumptions
Operating Condition Min Typical Max Unit
Radio On
*
(Discovery)
23 mA
Radio On
*
( Inquiry window time)
73 mA
Connected Idle (No Sniff)
20 mA
Connected with data transfer
6 10 25 mA
Table 11: Power consumptions
*If in SLAVE mode there are bursts of radio ON time which vary with the windows. Depending on how you set the
windows that determines your average current.
5.4 Input/output Terminal Characteristics
5.4.1 Digital Terminals
Supply Voltage Levels Min Typical Max Unit
Input Voltage Levels
Rating Min Max Unit
Storage Temperature -40 +120 °C
Operating Temperature -40 +85 °C
PIO/AIO Voltage -0.4 +3.6 V
VDD Voltage -0.4 +3.7 V
USB_DP/USB_DN Voltage -0.4 +3.6 V
Other Terminal Voltages except RF -0.4 VDD+0.4 V