User's Manual

FLC-BTM501 Datasheet
Flaircomm Microelectronics Confidential
-21-
5. Electrical Characteristic
5.1 Absolute Maximum Rating
Table 7: Absolute Maximum Rating
5.2 Recommended Operating Conditions
Operating Condition
Min
Typical
Max
Unit
Storage Temperature
-40
--
+85
°C
Operating Temperature Range (for A and I grade)
-40
--
+85
°C
Operating Temperature Range (for V and C grade)
-20
--
+70
°C
VDD_3V3 Voltage
+2.7
+3.3
+3.6
V
Table 8: Recommended Operating Conditions
5.3 Input/output Terminal Characteristics
5.3.1 Digital Terminals
Supply Voltage Levels
Min
Typical
Max
Unit
Input Voltage Levels
VIL input logic level low
-0.3
-
+0.25xVDD
V
VIH input logic level high
0.625VDD
-
VDD+0.3
V
Output Voltage Levels
V
OL
output logic level low, l
OL
= 4.0mA
-
-
0.125
V
V
OH
output logic level high, l
OH
= -4.0mA
0.75xVDD
-
0.625xVDD
V
Input and Tri-state Current
Ii input leakage current at Vin=VDD or 0V
-100
0
100
nA
Ioz tri-state output leakage current at Vo=VDD or 0V
-100
0
100
nA
With strong pull-up
-100
-40
-10
μA
With strong pull-down
10
40
100
μA
Rating
Min
Max
Unit
Storage Temperature
-40
+120
°C
PIO/AIO Voltage
-0.4
+3.6
V
VDD_3V3 Voltage
-0.4
+3.6
V
USB_DP/USB_DN Voltage
-0.4
+3.6
V
Other Terminal Voltages except RF
-0.4
VDD+0.4
V