5. Electrical Characteristic
5.1 Absolute Maximum Rating
Table 9: Absolute Maximum Rating Recommended Operating Conditions
5.2 Recommend operation conditions
Operating Condition
Min
Typical
Max
Unit
Storage Temperature
-40
--
+85
°C
Operating Temperature Range (for A and I grade)
-40
--
+85
°C
Operating Temperature Range (for V and C grade)
-20
--
+70
°C
VDD Voltage
+2.7
+3.3
+3.6
V
Table 10: Recommended Operating Conditions
5.3 Power consumptions
Operating Condition
Min
Typical
Max
Unit
Radio On
*
(Discovery)
23
mA
Radio On
*
( Inquiry window time)
73
mA
Connected Idle (No Sniff)
20
mA
Connected with data transfer
6
10
25
mA
Table 11: Power consumptions
*If in SLAVE mode there are bursts of radio ON time which vary with the windows. Depending on how you set the
windows that determines your average current.
Rating
Min
Max
Unit
Storage Temperature
-40
+120
°C
Operating Temperature (for A and I grade)
-40
+85
°C
Operating Temperature (for V and C grade)
-20
+70
°C
PIO/AIO Voltage
-0.4
+3.6
V
VDD Voltage
-0.4
+3.7
V
USB_DP/USB_DN Voltage
-0.4
+3.6
V
Other Terminal Voltages except RF
-0.4
VDD+0.4
V