Installation Guide
Table Of Contents
- Safety and warnings
 - Components
 - Tools
 - Appliance and cavity dimensions
 - Cabinetry options
 - Stainless steel door panel and toe kick dimensions
 - Custom door panel and toe kick dimensions
 - Custom door panel installation dimensions
 - Custom door panel installation template
 - Door clearance
 - Electrical and plumbing
 - Before installation
 - Cavity preparation
 - Water and power supply connection
 - Top trim installation
 - Side brackets installation
 - Positioning into cabinetry
 - Aligning inside cabinetry
 - Door panel installation - stainless steel
 - Door panel installation - custom
 - Fixing to cabinetry
 - Water filter installation
 - Toe kick installation
 - Door and door trims installation
 - Cabinet trims installation — [A] Flexible spring clip method
 - Cabinet trims installation — [B] Fixed screw method
 - Final checklist
 
13
A
C
B
Floor
Left side 
of cavity
Electrical and water connections must be within 
this space if located behind the appliance
IMPORTANT!
●
Electrical connection should be located in an adjacent cabinet to either side 
oftheappliance or above the appliance cavity. 
●
We recommend to use an isolating switch that is easily accessible to the user 
aftertheappliance is installed.
WARNING!
●
Electrical shock hazard. Assume all parts are live. 
●
Disconnect supply before servicing and installation.
ELECTRICAL AND PLUMBING
ELECTRICAL AND PLUMBING CONNECTIONS
1
Recommended location for connections in adjacent area or unit
2
Alternative location for connections above the cavity
3
Alternative location for connections at rear of cavity
1
3
2
1
ELECTRICAL AND PLUMBING DIMENSIONS inches mm
A
Overall height of supply area 5 5/8 143
B
Overall width of supply area 29 3/4 756
C
Distance from right side of cavity 2  7/8 73
D
Distance from the floor 2 51
Note: Dimensions are based on minimum depth of cavity. 