Installation Guide - Integrated Refrigerator Freezer
Table Of Contents
6
5 ATTACH BRACKET ASSEMBLY TO CAVITY
For flush installation
3 Measure 4 1/4” (108mm) back from the ceiling front edge
of the cavity and mark a line (C) across the centre line.
4 Place the joiner bracket to ceiling surface.
●
Align Face1 to the marked line (C).
●
Align Face 2 along the centre line of the cavity.
For proud installation
5 Place the joiner bracket forward of the flush installation
location. To determine the location,
●
Measure the depth of the door panel that protrudes
from adjacent cabinetry front surface (D).
●
Calculate the distance (E) of proud installation location,
4 1/4” (108mm) – D = E
Face 2Face 2
Face 2Face 1
Attach top joiner bracket and fixing bracket to cavity
1 Attach the top joiner bracket to the cavity fixing bracket with M5x12 socket head cap
screws.
●
For 80” (2032mm) installation, use the upper slots of the cavity fixing bracket (A).
●
For 84” (2134mm) installation, use the lower slots of the cavity fixing bracket (B).
SCALE 1:10
84” (2134mm)
72” (1829mm)
D
ceiling front edge
C
41/4”
(108mm)
41/4”(108mm)
centre linecentre line
C
D
E
F
IMPORTANT!
●
Ensure the anti tip brackets are installed before attaching the cavity fixing bracket. Refer to separate ‘Installation guide’ supplied with your appliance.
●
Ensure the water and power supply are already connected, and door panels installed before attaching the cavity fixing bracket.
Note: illustration above shows cavity for RS36W84/RS9121W model.
A
B
top joiner bracket
cavity fixing bracket
6 Place the joiner bracket to the ceiling surface
●
Align Face 1 to the marked line (E)
●
Align Face 2 along the centre line of the cavity.
7 Fix the joiner bracket with 8x16 mush washer screws (F).
Loosely fix the screws to enable adjustment in the centre
of each slot of the joiner bracket.
2 Measure the width of the cavity. Mark a line on the ceiling along the centre of the cavity.