Installation Guide
Table Of Contents
- 1 Safety and warnings
- 2 Components
- 3 Tools
- 4 Appliance and cavity dimensions
- 5 Cabinetry options
- 6 Door panel dimensions
- 7 Custom door panel installation dimensions — RS32A72
- 7 Custom door panel installation dimensions — RS36A72
- 8 Custom door panel installation template (RS32A72)
- 8 Custom door panel installation template (RS36A72)
- 9 Door clearance
- 10 Electrical and plumbing
- 11 Before installation
- 12 Cavity preparation
- 13 Water supply connection
- 14 Power supply connection
- 15 Installation preparation
- 16 Top trim installation
- 17 Positioning into cabinetry
- 18 Aligning inside cabinetry
- 19 Door panel installation — stainless steel
- 20 Door panel installation — custom
- 21 Fixing to cabinetry
- 22 Water filter installation
- 23 Toe kick installation
- 24 Covers and trims installation
- 25 Cabinet trims installation — [A] flexible spring clip method
- 26 Cabinet trims installation — [B] fixed screw method
- 27 Final checklist
- 1 Consignes de sécurité et mises en garde
- 2 Pièces
- 3 Outils
- 4 Dimensions de l’appareil et de la cavité
- 5 Options d’armoires
- 6 Dimensions de panneau de porte
- 7 Dimensions d’installation de panneau de porte sur mesure — RS32A72
- 7 dimensions d’installation de panneau de porte sur mesure — RS36A72
- 8 GABARIT D’INSTALLATION DE PANNEAU DE PORTE sur mesure — RS32A72
- 8 GABARIT D’INSTALLATION DE PANNEAU DE PORTE sur mesure — RS36A72
- 9 DÉGAGEMENT DE LA porte
- 10 Raccordement électrique et plomberie
- 11 Avant l’installation
- 12 Préparation de la cavité
- 13 Connexion d'alimentation en eau
- 14 Connexion d'alimentatioN
- 15 préparation de l'installation
- 16 installation de la garniture supérieure
- 17 positionnement dans les armoires
- 18 alignement dans les armoires
- 19 installation de panneau de porte — En acier inoxydable
- 20 Installation de panneau de porte — sur mesure
- 21 Fixation aux armoires
- 22 Installation du filtre à eau
- 23 Installation de la plinthe
- 24 INSTALLATION DES GARNITURES DE PORTE ET TIROIR
- 25 Installation des garnitures de bâti — [A] méthode avec clip de fixation flexible
- 26 Installation des garnitures de bâti — [B] méthode avec vis fixée
- 27 Liste de vérification finale
15
A
C
B
!
IMPORTANT!
●
Electrical connection should be located in an adjacent cabinet to either side
oftheappliance or above the appliance cavity.
●
We recommend to use an isolating switch that is easily accessible to the user
aftertheappliance is installed.
WARNING!
●
Electrical shock hazard. Assume all parts are live.
●
Disconnect supply before servicing and installation.
ELECTRICAL AND PLUMBING CONNECTIONS
1
Recommended location for connections in adjacent area or unit
2
Alternative location for connections above the cavity
3
Alternative location for connections at rear of cavity
B
1
3
2
1
Electrical and water connections must be within this space if located
behind the appliance and must not protrude from the back wall.
RS32A72 RS36A72
ELECTRICAL AND PLUMBING DIMENSIONS in mm
A
Overall height of supply area 4 5/16" 110 4 5/16" 110
B
Overall width of supply area 2 15/16" 75 2 15/16" 75
C
Distance from left side of cavity 5 1/16" 129 5 1/6" 129
D
Distance from the floor 4 5/16" 110 4 5/16" 110
Note: Dimensions are based on minimum depth of cavity.
!
Do not locate water or electricity in this area, keep clear of connections.
!
CAUTION: Central area can only fit water outlet and electrical plug if they are placed within a recessed cavity.
* In this location the water tap needs to be recessed into the wall, the recess must allow for an 80mm bend radius for
the watertube.
C
A
D
Left side
of cavity
Floor
Optional electrical
and water connection
location*
b
!0 ELECTRICAL AND PLUMBING
31 1/2" (800mm)
31 1/2" (800mm)
5 15/16"
(150mm)
5 15/16"
(150mm)