ManualsBrandsFisher & Paykel ManualsCooking Appliances48 Inch Freestanding Smart Dual Fuel Range with 5 Sealed Dual Flow Burners™, Dual Oven, 6.9 cu. ft. Total Oven Capacity, Continuous Grates, Wi-Fi Enabled, Pyrolytic Self-Clean, Griddle, 15 Oven Functions, Touchscreen Interface, Halo-Illuminated Dials, Ful
Table Of Contents
- Safety and warnings
 - Parts supplied for installation
 - Product dimensions – 30" models
 - Product dimensions – 36" models
 - Product dimensions – 48" models
 - Clearance dimensions – all models
 - Backguard considerations
 - Ventilation requirements
 - Unpacking the range
 - Removing and refitting the oven door(s)
 - Location of electrical and gas supply
 - Electrical connection
 - Gas connection
 - Toe kick installation
 - Levelling the range
 - Cooktop burners
 - Leak testing
 - Installing the anti-tip bracket
 - Final checklist
 
11
VENTILATION REQUIREMENTS
VENTILATION UNIT ISLAND INSTALLATION RECOMMENDATIONS
Hood
A  min. 30" (762mm) max. 42 (762mm)
B  min. 36" (914mm) max. 42 (762mm)
C  min. 19" (480mm)
Blower
30" Range min. 550 CFM
36" Range min. 550 CFM
48" Range min. 1100 CFM
VENTILATION UNIT WALL INSTALLATION RECOMMENDATIONS
Hood
A  min. 30" (762mm) max. 42 (762mm)
B  min. 36" (914mm) max. 42 (762mm)
C  min. 19" (480mm)
Blower
30" Range min. 550 CFM
36" Range min. 550 CFM
48" Range min. 1100 CFM
Non-combustible Non-combustibleCombustible Combustible
z
Ventilation hoods and blowers are designed for use with single wall ducting, however some local building codes or inspectors may require double wall ducting and/or a damper. Consultlocal 
building codes and/or agencies before installing to ensure local requirements are met.
z
Hood blower speeds should be variable to reduce noise and loss of household air. The maximum speed should only be required when using the grill.
z
Due to a high volume of ventilation air, a source of make-up air (outside replacement air) is recommended. This is particularly important for tightly sealed and insulated homes. A reputable 
heating and ventilating contractor should be consulted.
C C
C C
A A
B B
ISLAND INSTALLATION WALL INSTALLATION