Installation Guide
15
ELECTRICAL FEEDER CABLE CONNECTION
IMPORTANT!
The power supply cable must be connected by a Fisher & Paykel trained and support service technician or qualified person.
Feeder cable section
Use a type of cable according to the applicable local regulations.
PENL
220-240 V AC
2 Unscrew the bottom terminal end of the strain relief
by using two spanners. Insert terminal into the power
suply cable, then insert the feeder cable into the strain
relief (ensure sealing ring stays secured inside the
strain relief).
IMPORTANT!
Do not to unscrew the strain relief from the cooker.
3 Connect the live, neutral and earth cables to the
terminal as shown above. Lock the power supply
cable in place by screwing the terminal end back
to the strain relief. Re-mount the screw cover back
onto to the cooker.
IMPORTANT!
The earth conductor should remain around
30mm longer than the others.
1 Remove the screws that hold the cover in place
at the back of the cooker.