Installation Guide

14
ELECTRICAL CONNECTION
IMPORTANT!
z
This cooker must be connected to the mains power supply only
by a suitably qualified person. This cooker must be earthed.
z
If the installation requires alterations to the domestic electrical system, call a qualified electrician. The electrician should also check that
theelectrical system is suitable for the electricity drawn by the cooker.
z
The appliance must be connected to the mains electricity supply, checking that the voltage corresponds to the value given in the rating plate
and that the electrical cable sections can withstand the load specified on the plate.
z
A suitable disconnection switch must be incorporated in the permanent wiring, mounted and positioned to comply with the local wiring rules
and regulations. Theswitch must be of an approved type installed in the fixed wiring and provide a 3mm air gap contact separation inall
poles in accordance with the local wiringrules.
z
A switch of the approved type with a 3mm air gap must be installed in the active (phase) conductor of the fixed wiring.
z
The switch must always be accessible.
z
The power supply cable must not touch any hot parts and must be positioned so that it does not exceed 75°C at any point.
z
This cooker must be connected to a suitable double pole control unit adjacent to the cooker. No diversity can be applied to this control unit.
z
This appliance must be connected to the electrical supply using a cable fitted with an appropriately rated plug. The plug must be compatible
with the socket-outlet fitted to the final subcircuit in the fixed wiring that is intended to supply the appliance.
Replacing the power cord
z
Replacements should only be made by a qualified electrician.
z
Use a cable according to the applicable local regulations.
MODEL CODE MAX POWER (W) HZ VOLTAGE (V) AMPS (A)
OR90S*1 10610 50 Hz 220–240 V~ 46.13
OR90S*4 15300 50 Hz 220–240 V~ 66.54
OR90S*6 15550 50 Hz 220–240 V~ 67.6
location of
nameplate