Installation Guide

7
CLEARANCE DIMENSIONS
ISO
FRONT
F
CLEARANCE DIMENSIONS
OR90 DUAL FUEL
MM
A Minimum vertical distance between benchtop and cabinet
extending above counter
450
B Minimum clearance from left and right edge of cooker to nearest
vertical combustible surface
200
C Minimum clearance from cooking surface to:
z
Overhead cabinet centered above the cooktop
z
Ventilation hood centered above the cooking surface
650
650
D Width of cabinetry opening 900
E Maximum height of cabinetry immediately adjacent
to the cooker (from floor to countertop)*
946
F Maximum depth from wall to cabinetry face 600
*Depending on the height of the feet adjustment.
The cooking surface must sit flush or above benchtop level.
Note:
z
The cooker must be installed by a suitably qualified technician and in compliance
withlocal safety standards.
z
This cooker has class ‘2/1’ overheating protection so that it can be installed
next toacabinet
z
If the cooker is installed adjacent to furniture which is higher than the gas hob cooktop,
agap of at least 200mm must be left between the side of the cooker and the furniture.
z
The walls and kitchen furniture surrounding the appliance must be made of
non-flammable material. Anyveneered synthetic material and the glue used must
be resistant to a temperature of 90°C in order to avoid ungluing or deformations.
Itisrecommended that a 10mm gap to each side is made if the adjacent kitchen
furniture is made of a plastic laminate wrap.
z
Curtains must not be fitted immediately behind appliance or within 500mm of thesides.
Installing the cooker on a plinth
z
We do not recommend the cooker is installed on a plinth. If this is unavoidable,
thecooker can be installed on a plinth without the adjustable feet fitted.
z
Ensure the cooker is secure and provide safety measures to keep it in place.
z
Cabinetry dimensions can be adjusted to suit the plinth height, see product dimensions
for chassis height.
A
C
d
e
bb
Cooking surface
Electrical & Gas