Installation Guide
7
CLEARANCE DIMENSIONS
ISO
FRONT
F
CLEARANCE DIMENSIONS
OR90 DUAL FUEL
MM
A Minimum vertical distance between benchtop and cabinet
extending above counter
450
B Minimum clearance from left and right edge of cooker to nearest
vertical combustible surface
200
C Minimum clearance from cooking surface to:
z
Overhead cabinet centered above the cooktop
z
Ventilation hood centered above the cooking surface
650
650
D Width of cabinetry opening 900
E Maximum height of cabinetry immediately adjacent
to the cooker (from floor to countertop)*
946
F Maximum depth from wall to cabinetry face 600
*Depending on the height of the feet adjustment.
The cooking surface must sit flush or above benchtop level.
Note:
z
The cooker must be installed by a suitably qualified technician and in compliance
withlocal safety standards.
z
This cooker has class ‘2/1’ overheating protection so that it can be installed
next toacabinet
z
If the cooker is installed adjacent to furniture which is higher than the gas hob cooktop,
agap of at least 200mm must be left between the side of the cooker and the furniture.
z
The walls and kitchen furniture surrounding the appliance must be made of
non-flammable material. Anyveneered synthetic material and the glue used must
be resistant to a temperature of 90°C in order to avoid ungluing or deformations.
Itisrecommended that a 10mm gap to each side is made if the adjacent kitchen
furniture is made of a plastic laminate wrap.
z
Curtains must not be fitted immediately behind appliance or within 500mm of thesides.
Installing the cooker on a plinth
z
We do not recommend the cooker is installed on a plinth. If this is unavoidable,
thecooker can be installed on a plinth without the adjustable feet fitted.
z
Ensure the cooker is secure and provide safety measures to keep it in place.
z
Cabinetry dimensions can be adjusted to suit the plinth height, see product dimensions
for chassis height.
A
C
d
e
bb
Cooking surface
Electrical & Gas
(see diagrams following)