Installation Guide

17
FLAME TESTING
z
The operation of the appliance must be tested when installation is completed.
z
Turn on the appliance gas controls and light each burner individually and in combination. Check for a well defined blue flame
without any yellow tipping.
z
If any abnormality is evident then check that the burner cap is located properly and the injector nipple is aligned correctly.
z
Check the minimum burner setting by quickly rotating the gas control knob from the maximum to the minimum position.
Theflamemust not go out. If adjustment is required see section ‘Adjusting the minimum burner setting’.
If correct burner operation cannot be achieved, the installer shall check the installation and contact the local gas supply authority
toensure there are no gas supply problems. If correct operation still cannot be achieved contact Customer Service.
LEAK TESTING
z
Ensure all oven and burner knobs are set to OFF before
connecting cooker to gas supply.
z
After final gas connection is made, turn gas supply on and test
all connections in gas supply piping for gas leaks with a soapy
water solution.
z
In order to avoid property damage or serious personal injury,
never use a Iighted match or open flame.
If a leak is present, tighten joint or unscrew, apply more joint
compound, tighten again and retest connection for leak.
It is the responsibility of the gas installer to ensure that the
product is fully tested and commisioned in accordance with
current regulations to ensure there are no gas escapes.
lifting off yellow tip good flame
ON
GAS