Installation Guide

15
NG LPG
GAS CONNECTION
WARNING:
Only a suitably qualified and registered installer, also with technical knowledge of electricity should
installtheappliance. They should observe the Regulations and Codes of Practice governing such installation of
gas appliances.
Note: It is recommended that the gas connection to the appliance is installed with a flexible hose connecting tube
made to BS669 or EN 14800.
Installation to Natural Gas (NG)
z
Installation to Natural Gas must conform
totheCodeof Practice, etc.
z
The supply pressure for Natural Gas is 20 mbar.
z
The installation must conform to the relevant
British/European Standards.
Installation to LP Gas (LPG)
z
When operating on Butane gas a supply
pressureof28–30 mbar is required.
z
When using Propane gas a supply pressure
of37mbar is required.
z
The installation must conform to the relevant
British/European Standards.
manifold
(gas inlet pipe)
fibre washer
manifold male
pipe fitting
connector
1/2" G cylindrical
(ISO 228–1) female
1/2" BSP female
1/2" G cylindrical
(ISO 228–1) male
Gas supply
z
The connection must be performed by an authorised
person according to the relevantstandards.
z
This appliance is suitable for use with Natural Gas or LPG.
Thegas cooker is shipped from the factory set and
adjusted for Natural Gas. It can be converted for use
withLPG following the instructions in this manual.
z
If the Natural gas/LPG conversion kit is not supplied
withthe appliance this kit canbepurchased by
contacting theAfter-Sales Service.
If connecting the gas with a flexible hose
z
The ambient temperature of the hose must not exceed
70°C. These hoses must be manufactured in accordance
with BSE669 part 1 or EN 14800 and be of the correct
construction for the type of gas being used.
z
Never use a hose designed for natural gas for supplying
LPG gas. (LPG hoses either havea red band or stripe
onthe rubber outer coating of the hose.)
z
The hose should not be crushed or trapped or be in
contact with sharp or abrasiveedges.