Installation Guide
13
ELECTRICAL CONNECTION
IMPORTANT!
z
This cooker must be connected to the mains power supply only by a suitably qualified
person in accordance with current regulations. This cooker must be earthed.
z
The appliance must be connected to the mains checking that the voltage corresponds to the value given
in the rating plate and that the electrical cable sections can withstand the load specified on the plate.
z
It is recomended that the appliance is connected via a dedicated cooker circuit using a double pole
cooker switch with a rating equal or greater than the total loading of the cooker, with a minimum
opening between the contacts of 3mm.
z
Alternative connection methods may be available as long as they conform to current
IEE wiring regulations.
z
The power supply cable must not touch the hot parts and must be positioned so that it does not exceed
75°C at any point.
z
Once the appliance has been installed, the switch or socket must always be accessible within 2 metres.
z
Before carrying out any work on the electrical parts of the appliance, the appliance must be
disconnected and locked off from the mains.
z
This appliance must be connected to the electrical supply using a cable fitted with an appropriately
rated plug. The plug must be compatible with the socket-outlet fitted to the final subcircuit in the fixed
wiring that is intended to supply the appliance.
Replacing the power cord
z
If the power supply cable is damaged it must be substituted by a suitable cable available in
the after sales service.
location of
nameplate