Installation Guide

20
J
Injectors for
outer crown
J
Injector for
inner crown
Inner crown
Injector
Outer crown
Injectors
@0GAS CONVERSION
Conversion to ULPG
This range can be used with Natural Gas or ULPG. It is shipped from the factory adjusted
for use with Natural gas.
Any conversion required must be performed by an authorised person or service agent.
The range is supplied with a set of injectors required for converting the range burners.
Refer to the following table to select the appropriate size injector. The nozzle diameters
(hundredths of a millimetre) are marked on the body of each injector.
IMPORTANT!
After converting the range repeat flame testing.
If the range has been disconnected and re-connected to the gas supply line repeat leak
testing.
After conversion to ULPG gas affix the supplied conversion label near the data plate on
the product, as well as at the beginning of this manual.
If the range is being converted for use ULPG, before connecting to the gas mains remove
the appliance gas regulator and replace with test point adaptor.
Replacing the cooktop burner injectors
1 Remove the pan supports, the burner caps and the flame spreaders.
2 Using a wrench substitute the nozzle injectors with those most suitable for the kind of gas
for which it is to be used.
3 Adjust the minimum burner setting (see “Adjusting the minimum burner setting”)
4 Refit the flame spreaders, the burner caps and the pan supports.
5 Fix the warning label (supplied with the conversion kit) stating that the cooker has been
converted for use with ULPG to the rear of the range. Ensure it is in close proximity to to
the gas inlet connection.
The burners are designed so that no regulation of the primary air is required.
Auxiliary, Semi-rapid and
Rapid burners
Triple ring burners
Injectors table
BURNERS
NATURAL GAS
1 kPa
GAS
CONSUMPTION
ULPG 2.75 kPa
GAS
CONSUMPTION
Ø INJECTOR
MM
MJ/HR
Ø INJECTOR
MM
MJ/HR
Auxiliary (A) 0.92 3.90 0.56 3.90
Semirapid (SR) 1.17 6.5 0.70 6.3
Rapid (R) 1.54 11.75 0.98 11.75
Triple Ring (TR) 1.75 14.40 1.07 14.40
Dual (D)
Inner crown
injector
0.76
16.20
1
0.48
16.20
1
Outer crown
injector (x2)
1.23 0.71
1 Power calculated with inner and outer crown operating
Injector
Injector
Dual burner