Installation Guide

19
!8FLAME TESTING
The operation of the appliance must be tested when installation is completed.
Turn on the appliance gas controls and light each burner individually and in combination. Check for a well defined blue
flame without any yellow tipping. If any abnormality is evident then check that the burner cap is located properly and the
injector nipple is aligned correctly.
Check the minimum burner setting by quickly rotating the gas control knob from the maximum to the minimum position.
The flame must not go out. If adjustment is required see section “Adjusting the minimum burner setting”
If correct burner operation cannot be achieved, the installer shall check the installation and contact the local gas supply
authority to ensure there are no gas supply problems. If correct operation still cannot be achieved contact Customer
Service.
GAS
ON
GAS
ON
!9LEAK TESTING
Make sure all oven and burner knobs are set to OFF before connecting range to gas supply.
After final gas connection is made, turn gas supply on and test all connections in gas supply piping for gas leaks with
a soapy water solution.
In order to avoid property damage or serious personal injury, never use a Iighted match or open flame.
If a leak is present, tighten joint or unscrew, apply more joint compound, tighten again and retest connection for leak.
Lifting off
Yellow tip
Good flame